Data Sheet

TIM 2SM Series, 2 Watt
http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load 9 Vin models: tbd
12 Vin models: tbd
24 Vin models: tbd
48 Vin models: tbd
Surge voltage (3 sec. max.) 9 Vin models: 15 V max.
12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Reflected input ripple current 9 Vin models: tbd
12 Vin models: tbd
24 Vin models: tbd
48 Vin models: tbd
Start-up voltage 9 Vin models: tbd
12 Vin models: tbd
24 Vin models: tbd
48 Vin models: tbd
Startup time tbd
Under voltage shut down 9 Vin models: tbd
12 Vin models: tbd
24 Vin models: tbd
48 Vin models: tbd
Conducted noise EN55022 class A, B (with external filter)
EMC immunity – ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
– Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
– Fast transient / surge EN 61000-4-4, ±2 kV, perf. criteria A
(with external input capacitor) EN 61000-4-5, ±1 kV perf. criteria A
all models: tbd
– Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
– Magnetic field immunity EN 61000-4-8
100 A/m, continuous, perf. criteria A
1000 A/m, 1 sec., perf. criteria A
Output Specifications
Voltage set accuracy ±1 % max.
Regulation – Input variation 0.2 % max.
– Load variation 0 – 100 % 1 % max.
– Cross regulation dual output: 5.0 % max. (asymmetrical load 25/100 %)
Minimum load not required
Ripple and noise (20 MHz Bandwidth) 50 mVp-p typ.
Transient response (25% load step change)
– Recovery time 500 s typ.
Short circuit protection Continuous, automatic recovery