Datasheet

EN 61000-6-3 (Generic Residential)
- Conducted Emissions
EN 55014-1 (internal filter)
EN 55032 class B (internal filter)
- Radiated Emissions
EN 55014-1 (internal filter)
EN 55032 class B (internal filter)
- Harmonic Current Emissions
EN 61000-3-2, class A
EN 61000-6-2 (Generic Industrial)
EN 61204-3 (Low Voltage Power Supplies)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria B
Contact:
EN 61000-4-2, ±4 kV, perf. criteria B
- RF Electromagnetic Field
EN 61000-4-3, 3 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±0.5 kV, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria B
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 3 Vrms, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 0.5 periods, perf. criteria A
60%, 5 periods, perf. criteria B
115 VAC / 60 Hz:
EN 61000-4-11
30%, 0.5 periods, perf. criteria B
60%, 5 periods, perf. criteria B
EMC Specifications
100% max.
- Operating Temperature
–25°C to +50°C (without derating)
(Please take heat sources (such as lamps) nearby
into consideration for ambient temperature of the
power supply.)
- Low Input Voltage
0.45 %/V below 187 VAC (down to 132 VAC)
0.67 %/V below 115 VAC (down to 90 VAC)
0.3 %/V below 224 VDC (down to 142 VDC)
0.5 %/V below 120 VDC (down to 90 VDC)
- Protection Mode
140°C typ. (Automatic recovery)
- Measurement Point
Internal IC temperature
Natural convection (20 LFM)
3'000 m max.
Reinforced Insulation
- Input to Output, 60 s
3'000 VAC
- Touch Current
0.25 mA max.
- Calculated MTBF
(Please refer to application-note.)
- Vibration
IEC 60068-2-6
5 g, 3 axis, sine sweep, 60-500 Hz
- Mechanical Shock
IEC 60068-2-27
50 g, 3 axis, half sine, 11 ms
IP 67 (acc. IEC 60529)
Plastic (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated) (variant 1)
Polyurethane (UL 94 V-2 rated) (variant 2)
Plastic Case
Chassis Mount
Flying Leads
80 g
General Specifications
TIW 12 Series, 12 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 3 / 4