Datasheet

Input Voltage
Operational Range:
90 - 264 VAC (Full Range)
Rated Range:
100 - 240 VAC (Full Range)
Operational Range:
90 - 370 VDC (Designed for, no certification)
Polarity:
+DC: L / –DC: N
Input Frequency
Operational Range:
47 - 63 Hz
Certified:
50/60 Hz
Power Consumption
300 mW max. (Ready to meet ErP directive)
300 mW max.
Input Inrush Current
24 A max.
12 A max.
Recommended Input Fuse
6'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Voltage Set Accuracy
±3% max.
Regulation
1% max.
2% max.
Ripple and Noise
(20 MHz Bandwidth)
200 mVp-p max.
Minimum Load
Not required
Hold-up Time
20 ms min.
5 ms min.
Start-up Time
1'000 ms max.
1'000 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
250% max. of Iout max.
Output Specifications
Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
EN 60335-1
IEC 60335-1
EN 50178
IEC 62103
EN 61347-1
EN 61347-2-13
VDE 0710-14
EN 61558-1
EN 61558-2-8
EN 61558-2-16
www.tracopower.com/overview/tiw24
Protection Class
Class I & II (Prepared): Reinforced Insulation
Class 2 Power Units
UL 1310
Safety Specifications
EMI Emissions
EN 61000-6-3 (Generic Residential)
EN 55014-1 (internal filter)
EN 55032 class B (internal filter)
EN 55014-1 (internal filter)
EN 55032 class B (internal filter)
EN 61000-3-2, class A
EMC Specifications
TIW 24 Series, 24 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023