Input Voltage
Operational Range:
90 - 305 VAC (Full Range)
Rated Range:
100 - 277 VAC (Full Range)
Operational Range:
120 - 430 VDC (Designed for, no certification)
Polarity:
irrelevant
Input Frequency
Operational Range:
47 - 440 Hz
Certified:
50/60 Hz
Input Current
400 mA max.
600 mA max.
Power Consumption
300 mW max. (Ready to meet ErP directive)
300 mW max.
Input Inrush Current
60 A max.
30 A max.
(For the 7 & 15 W models an external Thermistor
has to be integreated in the circuit at the
converter input L in series.
Thermistor recommendation: 10R / 15z)
Recommended Input Fuse
3'150 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Voltage Set Accuracy
±2% max.
Regulation
0.5% max.
1.5% max. (3.3 VDC model)
1% max. (other models)
Ripple and Noise
(20 MHz Bandwidth)
3.3 VDC model:
33 mVp-p max. (w/ 0.1 µF || 47 µF)
5 VDC model:
120 mVp-p max. (w/ 0.1 µF || 47 µF)
12 VDC model:
120 mVp-p max. (w/ 0.1 µF || 47 µF)
15 VDC model:
150 mVp-p max. (w/ 0.1 µF || 47 µF)
24 VDC model:
240 mVp-p max. (w/ 0.1 µF || 47 µF)
Capacitive Load
3.3 VDC model:
6'800 µF max.
5 VDC model:
6'800 µF max.
12 VDC model:
1'600 µF max.
15 VDC model:
1'200 µF max.
24 VDC model:
470 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
50 ms min.
10 ms min.
Start-up Time
250 ms max.
400 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
172 - 268% of Iout max.
Overvoltage Protection
105 - 145% of Vout nom.
(By Zener diode)
Transient Response
2% max. (75% to 100% Load Step)
500 µs typ. (75% to 100% Load Step)
Output Specifications
TMG 30 Series, 30 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 27, 2023
Page 2 / 4