Input Voltage
Operational Range:
85 - 264 VAC (Full Range)
Rated Range:
100 - 240 VAC (Full Range)
Operational Range:
120 - 370 VDC (Designed for, no certification)
Polarity:
irrelevant
Input Frequency
Operational Range:
47 - 440 Hz
Certified:
50/60 Hz
Input Current
5.1 VDC model:
530 mA max.
12 VDC model:
600 mA max.
15 VDC model:
600 mA max.
24 VDC model:
600 mA max.
48 VDC model:
600 mA max.
5.1 VDC model:
880 mA max.
12 VDC model:
1'000 mA max.
15 VDC model:
1'000 mA max.
24 VDC model:
1'000 mA max.
48 VDC model:
990 mA max.
Power Consumption
750 mW max.
500 mW max.
Input Inrush Current
60 A max.
30 A max.
Input Protection
T 2 A / 250 VAC (Internal Fuse in L & N)
Recommended Input Fuse
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Voltage Set Accuracy
±2% max.
Regulation
1% max.
1% max.
Ripple and Noise
(20 MHz Bandwidth)
5.1 VDC model:
160 mVp-p max.
12 VDC model:
180 mVp-p max.
15 VDC model:
230 mVp-p max.
24 VDC model:
360 mVp-p max.
48 VDC model:
720 mVp-p max.
5.1 VDC model:
110 mVp-p typ.
12 VDC model:
120 mVp-p typ.
15 VDC model:
150 mVp-p typ.
24 VDC model:
240 mVp-p typ.
48 VDC model:
480 mVp-p typ.
Capacitive Load
5.1 VDC model:
8'000 µF max.
12 VDC model:
3'900 µF max.
15 VDC model:
3'300 µF max.
24 VDC model:
1'500 µF max.
48 VDC model:
680 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
50 ms min.
10 ms min.
Start-up Overshoot Voltage
5% max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
105% min. of Iout max.
Overvoltage Protection
120% typ. of Vout nom.
(By Zener diode)
Output Specifications
TMM 60 Series, 60 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 2 / 4