Datasheet

Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
UL 508
EN 60601-1
IEC 60601-1
ANSI/AAMI ES 60601-1
CSA-C22.2, No 60601-1
2 x MOPP (Means Of Patient Protection)
www.tracopower.com/overview/tmm60
Protection Class
Class I & II (Prepared): Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
EN 61000-6-3 (Generic Residential)
EN 61000-6-4 (Generic Industrial)
EN 55011 class B (internal filter)
EN 55032 class B (internal filter)
FCC Part 15 class B (internal filter)
EN 55011 class B (internal filter)
EN 55032 class B (internal filter)
FCC Part 15 class B (internal filter)
EMS Immunity
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-6-1 (Generic Residential)
EN 61000-6-2 (Generic Industrial)
EN 60601-1-2 edition 4 (Medical Devices)
Air:
EN 61000-4-2, ±15 kV, perf. criteria A
Contact:
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
EN 61000-4-6, 10 Vrms, perf. criteria A
Continuous:
EN 61000-4-8, 30 A/m, perf. criteria A
230 VAC / 50 Hz:
30%, 25 periods, perf. criteria A
>95%, 0.5 periods, perf. criteria A
>95%, 1 period, perf. criteria A
>95%, 250 periods, perf. criteria B
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
–40°C to +80°C
–40°C to +95°C
Power Derating
4.5 %/K above 60°C (5 Vin model)
3.8 %/K above 60°C (other models)
See application note:
www.tracopower.com/overview/tmm60
Cooling System
Natural convection (20 LFM)
Altitude During Operation
5'000 m max.
Switching Frequency
100 kHz typ. (PWM)
Insulation System
Reinforced Insulation
Working Voltage (rated)
240 VAC
Isolation Test Voltage
4'000 VAC
General Specifications
TMM 60 Series, 60 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023