Datasheet

Input Voltage
85 - 264 VAC (Full Range)
100 - 240 VAC (Full Range)
Input Frequency
47 - 63 Hz
50/60 Hz
Power Consumption
- No load & Vin = 230 VAC
200 mW max. (Ready to meet ErP directive)
- No load & Vin = 115 VAC
200 mW max.
Input Inrush Current
- At 230 VAC
50 A max.
- At 115 VAC
25 A max.
Power Factor
- At 230 VAC
0.45 min.
- At 115 VAC
0.55 min.
Input Protection
T 2 A (Internal Fuse)
Recommended Input Fuse
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Voltage Set Accuracy
±2% max.
Regulation
- Input Variation (Vmin - Vmax)
0.5% max.
- Load Variation (10 - 90%)
1% max. (12 Vout and 24 Vout model)
2% max. (5 Vout model)
Ripple and Noise
(20 MHz Bandwidth)
140 mVp-p max.
Capacitive Load
10'000 µF max.
Minimum Load
Not required
Temperature Coefficient
±2 %/K max.
Hold-up Time
- At 230 VAC
40 ms min.
- At 115 VAC
7 ms min.
Start-up Time
- At 230 VAC
500 ms max.
- At 115 VAC
500 ms max.
Start-up Overshoot Voltage
5% max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
105 - 150% of Iout max.
Overvoltage Protection
130% typ. of Vout nom.
120 - 160% of Vout nom.
Transient Response
- Response Deviation
5% max. (10% to 90% Load Step)
- Response Time
2'000 µs max. (10% to 90% Load Step)
Output Specifications
TMW 24 Series, 24 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023