Datasheet

Power Derating
- High Temperature
2 %/K above 50°C
- Low Input Voltage
2 %/V below 100 VAC
Over Temperature
Protection Switch Off
- Protection Mode
85°C min. / 90°C typ. / 95°C max. (Automatic
recovery)
- Measurement Point
Case
Cooling System
Natural convection (20 LFM)
Altitude During Operation
5'000 m max. (4'000 m max. for IEC
61558-2-8)
Switching Frequency
25 - 140 kHz (PWM QR)
Insulation System
Reinforced Insulation
Isolation Test Voltage
- Input to Output, 60 s
4'000 VAC
- Input to Output, 1 s
4'000 VAC
Creepage
- Input to Output
8 mm min.
Clearance
- Input to Output
8 mm min.
Isolation Resistance
- Input to Output, 500 VDC
100 min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
1'100 pF typ. / 1'300 pF max.
Leakage Current
(at 240 VAC / 60 Hz)
- Touch Current
100 µA max.
Distance Through Isolation
2 mm
Reliability
- Calculated MTBF
3'400'000 h (see application note)
(IEC 61709)
Environment
- Vibration
IEC 60068-2-6
3 g, 3 axis, sine sweep, 10-55 Hz, 1 oct/min
- Mechanical Shock
IEC 60068-2-27
25 g, 3 axis, half sine, 11 ms
Case Ingress Protection
IP 68 (acc. IEC 60529)
Housing Material
Plastic (UL 94 V-1 rated)
Potting Material
Polyurethane (UL 94 V-2 rated)
Housing Type
Plastic Case
Mounting Type
Chassis Mount
Connection Type
Flying Leads
Weight
131 g
Power Back Immunity
6.4 V max.
15 V max.
30 V max.
Environmental Compliance
- REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
- RoHS Declaration
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
- SCIP Reference Number
d74cdb40-a5ec-4615-94fa-4e45df94bd0c
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tmw24
TMW 24 Series, 24 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023