Datasheet

http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
AC/DC Power Supplies
TOP-100 Series 100 Watt
Input Specifications
Input voltage range 90 – 132 / 187 – 264 VAC autorange
Input frequency 47 – 63 Hz
Input protection T4 A/250 V internal fuse in both line & neutral
Zero load power consumption 3.6 W
Recommended circuit breaker 6 A (characteristic C) or slow blow fuse
Output Specifications
Regulation – Input and Load variation 1% max.
Ripple and noise (20Mhz Bandwidth) < 100 mVp-p
48 VDC model: < 200 mVp-p
Overvoltage protection 3.3 VDC model: 5.0 V
5.0 VDC model: 6.0 V
12 VDC model: 16 V
15 VDC model: 20 V
24 VDC model: 30 V
48 VDC model: 60 V
Power back immunity 3.3 VDC model: 5.0 V (6.0 V for 1 sec)
5 VDC model: 6.3 V (7.0 V for 1 sec)
12 VDC model: 16 V (18 V for 1 sec)
15 VDC model: 20 V (23 V for 1 sec)
24 VDC model: 35 V (40 V for 1 sec)
48 VDC model: 63 V (68 V for 1 sec)
Overload protection by current limit at 150 % Iout max.
Short circuit protection foldback (automatic recovery)
Capacitive load 10’000 µF max.
General Specifications
Operating Temperature – 25°C to +70°C with derating
Power derating see graph page 3
Temperature coefficient 0.02 % /K
Reliability, calculated MTBF @ 25°C acc. to IEC 61709 3.3 – 12 VDC models: >1.0 Mio h
15 – 48 VDC models: >1.4 Mio h
Humidity (non condensing) 0 – 95 % rel. H max.
Efficiency – Vin = 115 VAC 89 – 91%
– Vin = 230 VAC 90 – 92%
Switching frequency 100 kHz typ. (pulse width modulation)
Hold-up time – Vin = 115 VAC 10 ms typ.
– Vin = 230 VAC 15 ms typ.
Start-up time – Vin = 115 VAC < 3s
– Vin = 230 VAC < 2s
Isolation voltage – Input / Output 4000 VAC
– Input / Field Ground 2000 VAC
– Output / Field Ground 500 VAC
Isolation resistance (at 500 VDC) 100 Mohm min.
Earth leakage current 250 µA max.
Isolation class class II double isolation
Electromagnetic compatibility – Conducted input RI suppression EN 55022, class B (conductive plane to be
(EMC), emissions connected to safety earth)
– Harmonic current emissions IEC / EN 61000-3-2, class A