Datasheet

Overvoltage Protection
135% typ. of Vout nom.
(depending on model)
5 V typ. (3.3 Vout model)
6 V typ. (5 Vout model)
16 V typ. (12 Vout model)
20 V typ. (15 Vout model)
30 V typ. (24 Vout model)
60 V typ. (48 Vout model)
Transient Response
- Peak Variation
400 mV max. (10% to 90% Load Step)
- Response Time
3'000 µs max. (10% to 90% Load Step)
Safety Standards
- IT / Multimedia Equipment
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
- Certification Documents
www.tracopower.com/overview/top100
Protection Class
Class I & II (Prepared): Reinforced Insulation
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
EN 61000-6-3 (Generic Residential)
- Conducted Emissions
EN 55032 class B (internal filter)
- Radiated Emissions
EN 55032 class B (internal filter)
- Harmonic Current Emissions
EN 61000-3-2, class A
(conductive plane to be connected to safety earth
to meet all EMI specifications)
EMS Immunity
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria A
L to L:
EN 61000-4-5, ±1 kV, perf. criteria A
L to PE:
EN 61000-4-5, ±2 kV, perf. criteria A
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
1 s:
EN 61000-4-8, 1000 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
115 VAC / 60 Hz:
EN 61000-4-11
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–25°C to +70°C
- Storage Temperature
–40°C to +80°C
Power Derating
- High Temperature
1.8 %/K above 40°C (3.3 Vout model)
2.0 %/K above 40°C (5 Vout model)
2.0 %/K above 50°C (other models)
- Low Input Voltage
3.8 %/V below 103 VAC (3.3 Vout model)
0.9 %/V below 207 VAC (3.3 Vout model)
3.8 %/V below 103 VAC (other models)
1.0 %/V below 207 VAC (other models)
Cooling System
Natural convection (20 LFM)
Altitude During Operation
2'000 m max.
Switching Frequency
100 kHz typ. (PWM)
Insulation System
Reinforced Insulation
General Specifications
TOP 100 Series, 100 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 3 / 5