Datasheet

EMI Emissions
EN 61000-6-3 (Generic Residential)
- Conducted Emissions
EN 55032 class B (internal filter)
- Radiated Emissions
EN 55032 class B (internal filter)
- Harmonic Current Emissions
EN 61000-3-2, class A
(conductive plane to be connected to safety earth
to meet all EMI specifications)
EMS Immunity
- RF Electromagnetic Field
EN 61000-4-3, 20 V/m, perf. criteria A
- EFT (Burst) / Surge
EN 61000-4-4, ±2 kV, perf. criteria B
L to L:
EN 61000-4-5, ±1 kV, perf. criteria B
L to PE:
EN 61000-4-5, ±2 kV, perf. criteria B
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
Continuous:
EN 61000-4-8, 100 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
20%, 250 periods, perf. criteria A
30%, 25 periods, perf. criteria A
60%, 10 periods, perf. criteria B
>95%, 1 period, perf. criteria B
115 VAC / 60 Hz:
EN 61000-4-11
20%, 250 periods, perf. criteria A
30%, 25 periods, perf. criteria B
60%, 10 periods, perf. criteria B
>95%, 1 period, perf. criteria B
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–25°C to +70°C
- Storage Temperature
–40°C to +80°C
Power Derating
- High Temperature
2 %/K above 40°C (12 & 15 Vout models)
2 %/K above 50°C (24 & 48 Vout models)
- Low Input Voltage
1 %/V below 115 VAC (12 & 15 Vout models)
1.5 %/V below 108 VAC (24 & 48 Vout models)
Cooling System
Natural convection (20 LFM)
Remote Control
- Voltage Controlled Remote
See application note:
www.tracopower.com/overview/top200
- Current Controlled Remote
See application note:
www.tracopower.com/overview/top200
Altitude During Operation
2'000 m max.
Switching Frequency
100 kHz typ. (PWM)
Insulation System
Reinforced Insulation
Isolation Test Voltage
- Input to Output, 60 s
3'000 VAC
- Input to Case or PE, 60 s
1'500 VAC
- Output to Case or PE, 60 s
500 VAC
Creepage
- Input to Output
7 mm min.
- Input to Case or PE
4 mm min.
- Output to Case or PE
1 mm min.
Clearance
- Input to Output
5 mm min.
- Input to Case or PE
2.5 mm min.
- Output to Case or PE
0.5 mm min.
Isolation Resistance
- Input to Output, 500 VDC
100 min.
Isolation Capacitance
- Input to Output, 100 kHz, 1 V
1'500 pF typ.
Leakage Current
- Earth Leakage Current
500 µA max.
- Touch Current
100 µA max.
Reliability
- Calculated MTBF
(see application note)
General Specifications
TOP 200 Series, 200 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023