Input Specifications
Input voltage – nominal 120 – 240 VAC (universal input)
– AC input range 85 – 264 with derating at low input
see power derating graph 1
Input frequency 47 – 63 Hz
Harmonic limits EN 61000-3-2, class A
Zero load power consumption 3.6 W
Recommended circuit breaker 6 A (characteristic C) or slow blow fuse.
For protection class II use two fuses
(line and neutral)
Output Specifications
Regulation – Input and Load variation 1.0 % max.
Ripple and noise (20Mhz Bandwidth) <120 mVp-p
<150 mVp-p for 48 VDC models
Overvoltage protection 12 & 15 VDC models: >150 % of Vout
24 & 48 VDC models: >125 % of Vout
Power back immunity 12 VDC model: 16 V (18 V for 1 sec)
15 VDC model: 20 V (23 V for 1 sec)
24 VDC model: 35 V (40 V for 1 sec)
48 VDC model: 63 V (68 V for 1 sec)
Overload protection by current limit at 120 – 150 % Iout max.
Short circuit protection foldback (automatic recovery)
Capacitive load 12 & 15 VDC models: 15’000 µF max.
24 VDC model: 4’000 µF max.
48 VDC model: 1’000 µF max.
General Specifications
Operating temperature 25°C to +70°C (convection cooling)
– derating see power derating graph 2
Power derating
200
160
120
80
40
0
Output Power [W]
Ambient Temperature [°C]
108 115 264
200
160
120
80
40
0
Output Power [W]
Input voltage [VAC]
Graph 1:
In respect to input voltage
Graph 2:
in respect to ambient temperature
12 & 15 VDC models
24 & 48 VDC models
85 0204
0607
0-25