Datasheet
Altitude During Operation
5'000 m max.
Switching Frequency
45 - 75 kHz (PWM QR)
Insulation System
Reinforced Insulation
Working Voltage (rated)
250 VAC
Isolation Test Voltage
- Input to Output, 60 s
4'000 VAC
- Input to Case or PE, 60 s
2'000 VAC
- Output to Case or PE, 60 s
2'000 VAC
Isolation Resistance
- Input to Output, 500 VDC
100 MΩ min.
Leakage Current
(at 264 VAC)
- Touch Current
100 µA max.
Reliability
- Calculated MTBF
786'000 h (MIL-HDBK-217F, ground benign)
Environment
- Vibration
IEC 60068-2-6
5 g, 3 axis, sine sweep, 10-500 Hz, 1 oct/min
- Mechanical Shock
IEC 60068-2-27
50 g, 3 axis, half sine, 11 ms
Housing Type
Open Frame
Mounting Type
Chassis Mount
Connection Type
Pin Connector
Weight
187 g
Environmental Compliance
- REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
- RoHS Declaration
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
- SCIP Reference Number
e0777432-36e5-453e-b34f-5037ee652740
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tpp150a-j
TPP 150A-J Series, 150 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 4 / 5