Datasheet
Input Voltage
- AC Range
Operational Range:
85 - 264 VAC (Full Range)
Rated Range:
100 - 240 VAC (Full Range)
- DC Range
Operational Range:
120 - 370 VDC (Designed for, no certification)
Polarity:
+DC: L / –DC: N
Input Frequency
Operational Range:
47 - 440 Hz
Certified:
50/60 Hz
Input Current
- Full Load & Vin = 230 VAC
400 mA max.
- Full Load & Vin = 115 VAC
800 mA max.
Power Consumption
- No load & Vin = 230 VAC
60 mW max. (Ready to meet ErP directive)
- No load & Vin = 115 VAC
60 mW max.
Input Inrush Current
- At 230 VAC
40 A max.
- At 115 VAC
25 A max.
Input Protection
T 1.6 A / 250 VAC (Internal Fuse in L & N)
Recommended Input Fuse
(The need of an external fuse has to be assessed
in the final application.)
Input Specifications
Output Voltage Adjustment
See application note:
±10% (By external trim resistor)
www.tracopower.com/overview/tpp30-d
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
0.2% max.
- Load Variation (0 - 100%)
0.7% max. (3.3 and 5 VDC model)
0.5% max. (other output models)
Ripple and Noise
(20 MHz Bandwidth)
3.3 VDC model:
50 mVp-p typ. (w/ 10 µF X7R)
5 VDC model:
50 mVp-p typ. (w/ 10 µF X7R)
9 VDC model:
50 mVp-p typ. (w/ 10 µF X7R)
12 VDC model:
50 mVp-p typ. (w/ 1 µF X7R)
15 VDC model:
50 mVp-p typ. (w/ 1 µF X7R)
24 VDC model:
50 mVp-p typ. (w/ 1 µF X7R)
36 VDC model:
50 mVp-p typ. (w/ 1 µF X7R)
48 VDC model:
50 mVp-p typ. (w/ 0.1 µF X7R)
Capacitive Load
3.3 VDC model:
10'000 µF max.
5 VDC model:
12'000 µF max.
9 VDC model:
3'720 µF max.
12 VDC model:
2'085 µF max.
15 VDC model:
1'350 µF max.
24 VDC model:
520 µF max.
36 VDC model:
235 µF max.
48 VDC model:
130 µF max.
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Hold-up Time
- At 115 VAC
16 ms min.
Start-up Time
- At 230 VAC
1'500 ms max.
Short Circuit Protection
Continuous, Automatic recovery
Output Current Limitation
110 - 170% of Iout max.
140% typ. of Iout max.
Overvoltage Protection
125 - 140% of Vout nom.
Transient Response
- Response Deviation
3% max. (50% to 75% Load Step)
- Response Time
500 µs typ. (50% to 75% Load Step)
Output Specifications
TPP 30-D Series, 30 Watt
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com September 20, 2023
Page 2 / 5