CAUTION To reduce the risk of fire and to properly exhaust air, be sure to duct air outside Do
not vent exhaust air into spaces with in walls or ceilings or into attics, crawl spaces, or garages.
CAUTION To reduce the risk of fire and electric shock, install this range hood only with Integral
Blower manufactured by Trade-Wind®.
PART 1 Planning the Installation
CAUTION:
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never
exhaust into a wall, an attic or a concealed area in the building. This can create a potential hazard.
4. Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.
5. Locate the cooking area for minimum cross draftsaway from doors and windows, when possible.
6. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary,
keep turning radius as large and as smooth as possible.
7. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct
joints with high quality duct tape.
8. Only use ductwork constructed of materials deemed acceptable by state, municipal and local codes.
9. Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum
clearances, unless otherwise specified.
IMPORTANT: If the Trade-Wind
®
hood is installed as a liner for a wood hood or custom hood, proper
installation of the hood as a liner is directly related to the material from which the custom canopy is
constructed. You must provide structural framing and tight backing in the areas in which you are securing
the liner inside your custom canopy. Failure to do so could distort and damage the hood and void the
warranty.
Dimensions:
Dimensions
Models
Width
CFM
Duct
Opening
H32306RC
30‖
600
8‖
H32366RC
36‖
600
8‖
H32426RC
42‖
600
8‖
Dimensions
Model
Width
CFM
Duct
Opening
H32487RC
48‖
780
10‖
Dimensions
Models
Width
CFM
Duct
Opening
H32303RC
30‖
390
7‖
H32363RC
36‖
390
7‖
H32423RC
42‖
390
7‖