Installation Guide
15
Additional Instructions/Notes:
• Always inspect the ooring thoroughly before installation.
• DO NOT slide heavy appliances or furniture over or across the ooring. Always lift objects and place them on
a hard board between the ooring and object and gently reposition them.
• In-oor heat/AC registers may rest on the vinyl oor, but leave space under registers that are attached to
the oor or wall. They should not pinch the ooring material. Be sure to allow a larger opening around the
screw to enable movement.
• Apply caulk next to bathtubs, showers, sliding doors, patio doors, around metal door jambs or similar areas.
• For bathroom installations, it is not necessary to remove the toilet. Make relief cuts around the perimeter
of the toilet and make sure the vinyl ooring is laying at before trimming o the excess material. Apply
caulk around the toilet, next to the bathtubs and showers to prevent moisture from getting under the vinyl.
NOTE: if there is a ceramic sanitary cove and no place to install trim mold, you can apply caulk around the
walls.
• Make sure furniture legs have large surface, non-staining plastic oor protectors or non-staining felt pads.
The protectors should be at least one inch in diameter and rest at on the oor. The heavier the item, the
wider the oor protector should be. Replace small, narrow metal or dome-shaped glides with smooth, at
glides that are in at contact with the oor.
• Never tape around the perimeter of the room.
• Never apply TracMaster ooring to a wet adhesive (if adhesive is needed for certain areas of the Loose-
Lay). This could cause permanent bond or wrinkling and possibly void the warranty.
Permanent Full Spread Installation Method (for “special needs” residential/
property management installations)
The Permanent Full Installation Method can be used for special needs areas, such as those with rolling
trac, extremely high trac or in areas where cabinets will be installed on ooring or areas with accelerated
concrete moisture up to 8 lbs. However, PLEASE NOTE that if you elect to permanently install your
TracMaster ooring using this method as opposed to the recommended Releasable Installation Method that
labor rates exceeding residential releasable removal and underlayment will not be covered.
Materials Required for Installation:
• 1/16” X 1/16” X 3/32” OR 1/16” X 1/16” X 1/16” X U notch trowel
• Roberts 2310 Adhesive
• Armstrong S-761 acrylic seam sealer
• Acrylic Latex Floor Primer
• Roberts MaxGrip Installation Tape
• Sharp Utility Knife
• Straight edge
• 100 lb. roller
• Plastic putty knife, 2 clean cloths and appropriate cleaner
Residential Installation Guide – Sheet Vinyl Flooring
This document is reviewed on an ongoing basis. 4/22/14