Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A N o t e : “Graphics in this document are for representation only. Actual model may differ in appearance.
Product Specifications 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 12 14 17 18 BR. CIR. PROT. RTG. — MAX. (AMPS) 20 25 25 30 CLIMATUFF®SCROLL CLIMATUFF®SCROLL CLIMATUFF®SCROLL CLIMATAUFF®SCROLL RL AMPS — LR AMPS 9 — 63 10.9 — 63 12.8— 68 14.1— 72 Outdoor Fan FL AMPS 0.60 0.60 0.77 0.77 Fan HP 1/15 1/15 1/8 1/8 Fan Dia (inches) 18.
Pr o d u c t S p e c i fi c a ti o n s Model No. (a) POWER CONNS. — V/PH/HZ (b) 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A 280/230/1/60 280/230/1/60 280/230/1/60 MIN. BRCH. CIR. AMPACITY 22 24 31 BR. CIR. PROT. RTG. — MAX. (AMPS) 35 40 50 CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL RL AMPS — LR AMPS 16.7 — 109 18.5 — 124 23.7 — 152.5 Outdoor Fan FL AMPS 0.93 0.95 0.95 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 27.5 27.5 27.
Accessory Description and Usage A n t i - S h o rt C y c l e T i m e r — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. E v a p o r a t i o n D e f r o s t C o n t r o l — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV.
Schematic Diagrams Figure 1. 1.5 — 4.
S ch e m a t i c D i a g r a m s Figure 2. 5.
Outline Drawing Model Base A B C 4TTR4018L 2 730 (28–3/4) 724 (28–1/2) 651 (25–5/8) 4TTR4024L 4TTR4025L 2 730 (28–3/4) 724 (28–1/2) 4TTR4030L 4TTR4031L 3 730 (28–3/4) 4TTR4036L 4TTR4037L 3 4TTR4042L 4TTR4043L E F G H J K 3/4 3/8 127 (5) 57 (2–1/4) 194 (7–5/8) 38 (1–1/2) 457 (18) 651 (25–5/8) 3/4 3/8 127 (5) 57 (2–1/4) 194 (7–5/8) 38 (1–1/2) 457 (18) 829 (32–5/8) 756 (29–3/4) 3/4 3/8 127 (5) 76 (3) 197 (7–3/4) 60 (2–3/8) 508 (20) 832 (32–3/4) 829 (32–5/8)
Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application.