Product Sheet
22-1904-1G-EN
3
Model No.
(a)
4TTR4042L1000A/
4TTR4043L1000A
4TTR4048L1000A 4TTR4060L1000A
POWER CONNS. — V/PH/HZ
(b)
280/230/1/60 280/230/1/60 280/230/1/60
MIN. BRCH. CIR. AMPACITY 22 24 31
BR. CIR. PROT. RTG. — MAX. (AMPS)
35 40 50
COMPRESSOR
CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL
RL AMPS — LR AMPS 16.7 — 109 18.5 — 124 23.7 — 152.5
Outdoor Fan FL AMPS 1.05 1.05 1.05
Fan HP
1/5 1/5 1/5
Fan Dia (inches)
27.5 27.5 27.5
Coil SPINE FIN™ SPINE FIN™ SPINE FIN™
Refrigerant R-410A 6 LBS., 7 OZ 6 LBS., 9 OZ 7 LBS., 10 OZ
LINE SIZE — IN. O.D. GAS
(c)
7/8 7/8 7/8
LINE SIZE — IN. O.D. LIQ.
(c)
3/8 3/8 3/8
Charge Spec. Subcooling
12°F 10°F 10°F
Dimensions H x W X D Crated (IN.)
34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7
Weight — Shipping (lbs.)
216 212 246
Weight — Net (lbs.)
184 189 211
Optional Accessories:
Anti-short Cycle Timer
TAYASCT501A TAYASCT501A TAYASCT501A
Evaporator Defrost Control
AY28X079 AY28X079 AY28X079
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101
Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004
Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263
Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301
Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001
Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103
Refrigerant Lineset
(d)
TAYREFLN7* TAYREFLN3* TAYREFLN3*
Service Valve Panel Cover AAYSVPANL0044AA
(a)
Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard
210/240.
(b)
Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
(c)
Standard line lengths — 60’, Standard lift — 60’ Suction and Liquid line. For Greater lengths and lifts refer to refrigerant
piping software Pub#32–3312–0* (* denotes latest revision)..
(d)
* = 15, 20, 25, 30, 40 and 50 foot lineset available.
PPrroodduucctt SSppeecciiffiiccaattiioonnss