Split System Heat Pump Product Data XL16i 4TWX6024, 036, 048 & 060E 2, 3, 4 & 5 Tons PUB. NO.
Features and Benefits • CLIMATUFF™ 2-stage scroll • Internal compressor high/low • • • • • • • • • • © 2011 Trane compressor Efficiency up to 18.0 SEER and 9.
Contents Features and Benefits 2 General Data 4 Product Specifications A-weighted Sound Power Level [dB(A)] Accessory Description and Usage AHRI Standard Capacity Rating Conditions Model Nomenclature Electrical Data Dimensions Mechanical Specifications 22-1754-17 3 4 4 5 5 6 7 10 11
General Data Product Specifications Model No. 1 4TWX6024E1 Electrical Data V/Ph/Hz 2 230/1/60 Min Cir Ampacity 14 Max Fuse Size (Amps) 20 Compressor CLIMATUFF® - SCROLL RL AMPS - LR AMPS 10.3 - 52 Outdoor Fan FL Amps 0.74 Fan HP 1/8 Fan Dia (inches) 27.6 Coil Spine Fin™ Refrigerant R-410A 10/3-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 Line Size - (in.) O.D. Liquid 3 3/8 Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.
General Data AHRI Standard Capacity Rating Conditions Accessory Description and Usage AHRI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.
Model Nomenclature Gas Furnaces Outdoor Units T U D 2 B 0 8 0 A C V 3 2 A A 4 T W X 6 0 3 6 E 1 0 0 0 A A Refrigerant Type 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial Family SEER 3 = 13 6 = 16 4 = 14 8 = 18 5 = 15 9 = 19 0 = 20 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or
Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6024 Printed from D156993P02 22-1754-17 7
Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6036E Printed from D156631P06 Rev 00 8 22-1754-17
Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6048E 1 2 5 Printed from D156977 22-1754-17 9
Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6060E A C R - A /C R E C T I F I E R C BS - C OI L BOT T OM SE NSOR C F - F A N C A PA C I T OR T O POWE R SUPPL Y PE R UNI T NA M E PL A T E A ND L OC A L C ODE S C N - W I R E C ONNE C T OR C PR - C OM PR E SSOR C R - R UN C A PA C I T OR SU MP HT R BK PR /WH C SR - C A PA C I T OR SW I T C HI NG R E L A Y PR /WH DF C - DE F R OST C ONT R OL E E V - E L E C T R ONI C E X P V A L V E CS M S-1 RD BK/BL ST A R T K I T BA Y K SK T 263 BR/RD GR
Dimensions 4TWX6 Outline Drawing Note: All dimensions are in MM (Inches).
Mechanical Specifications General The 4TWX6 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer.