UH-PRC001-EN 17
Performance Data
Steam Performance Data
Horizontal Unit Heaters
Performance based on 2# steam pressure at heater with air entering @ 60° F (max working pressure 150 PSI,366° F)
* For the lower output, an optional Speed Controller must be ordered.
For Sound Ratings, see the Technical and Mounting Data-portion of this chapter.
Ta b l e 7.
Model
No.
Total
MBh
Cond.
lbs./hr.
E.D.R.
Sq. Ft. LAT °F
Motor
HP
Motor
RPM
Nominal
CFM
Outlet
Velocity
FPM
Sound
Rating
S-18
18,000 18.0 75 102
16 Watts
1550 395 395 II
16,200 16.2 68 105 1350 330 330 I
S-24
24,000 24.5 100 109
16 Watts
1550 450 450 II
21,600 22.0 90 112 1350 380 380 I
S-36
36,000 37.0 150 119
25 Watts
1550 550 550 II
32,400 33.0 135 120 1350 480 480 I
S-48
48,000 49.0 200 119
1/20
1000 750 550 II
43,200 44.0 180 123 900 630 460 I
S-60
60,000 61.0 250 121
1/20
1000 900 650 II
54,000 55.0 225 131 900 700 510 I
S-72
72,000 73.0 300 120
1/20
1000 1100 800 II
64,800 66.0 270 123 900 950 700 I
S-84
84,000 85.0 350 115
1/12
1000 1400 900 III
75,600 76.0 315 123 900 1100 750 II
S-96
96,000 97.0 400 123
1/12
1000 1400 930 III
86,400 88.0 360 132 900 1100 800 II
S-108
108,000 110.0 450 115
1/12
1000 1800 1000 III
97,200 98.0 405 120 900 1500 900 II
S-120 120,000 122.0 500 118 1/3 1140 1900 900 III
S-132 132,000 134.0 550 121 1/3 1140 2000 950 IV
S-144 144,000 146.0 600 120 1/3 1140 2200 1000 IV
S-156 156,000 160.0 650 115 1/3 1140 2600 1150 IV
S-180 180,000 190.0 770 135 1/3 1140 2200 800 III
S-204 204,000 208.0 850 124 1/3 1140 2900 1000 IV
S-240 240,000 244.0 1000 123 1/3 1140 3500 900 IV
S-280 280,000 280.0 1100 121 1/2 1100 4200 980 IV
S-300 300,000 310.0 1250 117 1/2 1100 5000 700 IV
S-360 360,000 366.0 1500 120 1/2 1100 5500 1000 IV