Catalogue

24 UH-PRC001-EN
Performance Data
**Performance based on 200° EWT, 20° T.D., 60° E.A.T. Performance at 10° & 30° T.D. is also shown.
For capacities at other conditions, use the correction multipliers in Table 16, Table 17, Table 18, Table 19, and Table 20.
P-122
10° 83.7 17.24 2.40 95.4°
1/6 1100 2180 1390 III
20° 73.9 7.62 .51 91.3
30° 64.2 4.41 .18 87.1°
P-146L
10° 95.4 19.66 2.92 97.3°
1/6 1100 2360 1080 III
20° 85.5 8.81 .65 93.4°
30° 75.6 5.20 .24 89.5°
P-166L
10° 112.3 23.15 2.70 95.4°
1/6 1100 2920 1340 IV
20° 100.7 10.38 .60 91.8°
30° 89.2 6.13 .22 88.1°
P-202L
10° 135.8 27.98 3.85 96.9°
1/4 1100 3390 1560 III
20° 121.8 12.52 .85 93.0°
30° 107.3 7.37 .32 89.2°
P-252L
10° 168.5 34.72 6.75 94.5°
1/4 1100 4507 1270 IV
20° 153.8 15.85 1.56 91.4°
30° 139.1 9.56 .61 88.4°
P-280L
10° 188.9 25.95 3.92 94.5°
1/2 1100 5040 1420 IV
20° 180.1 18.56 2.10 92.9°
30° 162.7 11.18 .82 89.7°
P-336L
10° 220.9 30.35 5.26 95.7°
3/4 1140 5700 1610 IV
20° 210.6 21.70 2.81 94.1°
30° 189.9 13.05 1.09 90.7°
P-384L
10° 260.7 35.82 5.24 96.4°
3/4 1140 6600 1870 IV
20° 248.5 25.61 2.80 94.7°
30° 224.2 15.40 1.09 91.3°
P-500L
10° ----- ----- ----- -----
1-1/2 1160 9380 1860 IV
20° 310.5 32.00 4.23 90.5°
30° 281.7 19.35 1.67 87.7°
P-600L
10° 394.4 54.19 6.83 95.3°
1-1/2 1160 10,300 2060 IV
20° 377.0 38.85 3.68 93.7°
30° 342.2 23.51 1.45 90.6°
P-720L
10° ----- ----- ----- -----
3 1165 11,900 2380 IV
20° 453.7 46.76 4.11 95.1°
30° 411.7 28.28 1.62 91.9°
Table 15. Low Output Units Standard Model P Units with All Air Ports Open** (continued)
Model No.
Water
Temp.
Drop Total MBh GPM WPD LAT °F Motor HP RPM
Nominal
CFM
Outlet
Velocity
FPM Sound Rating