Digits 1, 2 - Unit Model
RT = Rotary chiller
Digit 3 - Unit Type
A = Air-cooled
Digit4-Development Sequence
C = Development sequence
Digits 5, 6 & 7 - Nominal
Capacity
140 = 140 Nominal tons
155 = 155 Nominal tons
170 = 170 Nominal tons
185 = 185 Nominal tons
200 = 200 Nominal tons
225 = 225 Nominal tons
250 = 250 Nominal tons
275 = 275 Nominal tons
300 = 300 Nominal tons
350 = 350 Nominal tons
400 = 400 Nominal tons
450 = 450 Nominal tons
500 = 500 Nominal tons
Digit 8 - Unit Voltage
A = 200/60/3
C = 230/60/3
J = 380/60/3
4 = 460/60/3
5 = 575/60/3
Digit 9 - Manufacturing Location
U = Water Chiller Business Unit,
Pueblo, CO USA
Digits 10, 11 - Design Sequence
XX = Factory Input
Digit 12 - Unit Basic
Configuration
N = Standard efficiency/performance
H = High efficiency/performance
A = Extra efficiency/performance
Digit 13 - Agency Listing
N = No agency listing
U = C/UL listing
S = Seismic rated - IBC and OSHPD
R = C/UL listed and seismic rated
Digit 14 - Pressure Vessel Code
A = ASME pressure vessel code
C = Canadian code
D = Australian code
L = Chinese code
Digit 15 - Evaporator Application
F = Standard (40-60 F) leaving temp
G = Low (Less than 40 F) leaving temp
R = Remote (40-60 F) leaving temp
Digit 16 - Evaporator
Configuration
N = 2 pass, 0.75” insulation
P = 3 pass, 0.75” insulation
Q = 2 pass, 1.25” insulation
R = 3 pass, 1.25” insulation
Digit 17 - Condenser Application
N = Standard ambient (25-115°F)
H = High ambient (25-125°F)
L = Low ambient (0-115°F)
W = Wide ambient (0-125°F)
Digit 18 - Condenser Fin Material
1 = Standard aluminum slit fins
2 = Copper fins
4 = CompleteCoat™ epoxy coated
fins
Digit 19 - Condenser Fan/Motor
Configuration
T = STD fans withTEAO motors
W = Low noise fans
Digit 20 - Compressor Motor
Starter Type
X = Across-the-line
Y = Wye-delta closed transition
Digit 21 - Incoming Power Line
Connection
1 = Single point power connection
2 = Dual point power connection
Digit 22 - Power Line Connection
Type
T = Terminal block connection
D = Non-fused disconnect switch(es)
C = Circuit breaker(s) )
Digit 23 - Unit Operator Interface
D = DynaView operator interface
Digit 24 - Remote Operator
Interface
N = No remote interface
C = Tracer™ Comm 3 interface
B = BACnet
®
interface
L = LonTalk
®
compatible (LCI-C)
interface
Digit 25 - Control Input
Accessories/Options
N = No remote inputs
R = Ext. evaporator leaving water
setpoint
C = Ext. current limit setpoint
B = Ext. leaving water and current
limit setpoint
Digit 26 - Control Output
Accessories/Options
N = No output options
A = Alarm relay outputs
C = Ice making I/O
D = Alarm relay outputs and ice
making I/O
Digit 27 - Electrical Protection
Options
0 = No short circuit rating
5 = Default short circuit rating
6 = High amp short circuit rating
Digit 28 - Flow Switch
T = Factory installed flow switch -
water
U = Factory installed flow switch
glycol
Digit 29 - Control Panel
Accessories
N = No convenience outlet
A = 15A 115V convenience outlet
(60Hz)
Digit 30 - Service Valves
1 = With suction service valves
Digit 31 - Compressor Sound
Attenuation Option
0 = No compressor sound
attenuation
1 = Factory installed compressor
sound attenuation
Digit 32 - Appearance Options
N = No appearance options
A = Architectural louvered panels
C = Half louvers
Digit 33 - Installation
Accessories
N = No installation accessories
F = Flange kit for water connections
R = Neoprene in shear unit isolators
G = Neoprene isolators and flange kit
E = Seismic elastomeric isolation
pads
S = Seismic spring isolators
Digit 34 - Factory Testing
Options
0 = Standard functional test
C = Customer-witnessed performance
test with report
C = Customer-witnessed performance
test plus Rapid Restart test
E = Non-witnessed performance test
with report
Digit 35 Control, Label &
Literature
C = Spanish
E = English
F = French
Digit 36 Special Order
X = Standard unit configuration
S = Unit has special order feature
Digit 37 Safety Devices
N = Standard