UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B100A9V3VB, TUD2C100A9V5VB TUD2C100B9V5VB, TUD2D120A9V5VB TUD2D120B9V5VB, TUD2D140A9V5VB Two-Stage FanAssisted CombustionSystem PUB. NO.
General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standart rating conditions using American National Standards Instirute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heaating mode of operation.
Contents Feature Summary 2 Features and Benefits 4 Standard Equipment Optional Equipment General Data 4 5 6 TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B100A9V3VB TUD2C100A9V5VB TUD2C100B9V5VB TUD2D120A9V5VB TUD2D120B9V5VB TUD2D140A9V5VB 22-1650-13 Performance Data 9 Electric Data 19 Field Wiring Diagrams 19 Dimensions 24 3
Features and Benefits XV80 STANDARD EQUIPMENT • • • • • • • • • • • • • • • Upflow/Horizontal and Power supply 115/1/60 2-stage gas valve 2-speed venter Variable speed blower motor Silicon Nitride hot surface igniter with adaptive heat up Integrated solid state control Attractive color accents Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Complete front service access Alternate bottom/left/right return air Slide out blower assembly Hinged blower door Perfect fit door catches 4 •
Features and Benefits XV80 OPTIONAL EQUIPMENT Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling......................................................................................... TAYSTAT241 [ Thermostat, Mechanical Heating Only With Fan Switch.............................................................................................. BAYSTAT303 [ Thermostat, Mechanical Heating Only...................................................................................................................
GENERAL DATA TUD-R9V PRODUCT SPECIFICATIONS1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (In.
TUD-R9V PRODUCT SPECIFICATIONS1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (In.
TUD-R9V PRODUCT SPECIFICATIONS1 MODEL TUD2C100B9V5VB 5 TUD2D120A9V5VB TUD2D120B9V5VB 5 TUD2D140A9V5VB Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal 65,000 52,000 100,000 79,000 35 - 65 78,000 62,400 120,000 97,000 35 - 65 78,000 62,400 120,000 97,000 35 - 65 91,000 72,800 140,000 111,000 40 - 70 Direct 10 x 10 1 Variable See Airflow Table 1 Variable 115/1/60 Direct 10 x 10 1 Variable See Airflow Table 1 Variable 115/1/60 Direct 10 x 10 1 Variable See Airflow
*UD2B060A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW7 EXTERNAL STATIC PRESSURE SW8 0.1 0.3 0.5 0.7 0.9 589 49 65 604 48 95 619 47 125 604 48 160 607 48 200 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 663 44 75 694 42 120 684 42 145 681 42 185 686 42 220 HIGH OFF OFF CFM TEMP.
*UD2B080A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 800 48 100 790 49 135 765 50 155 750 52 200 730 53 230 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 910 43 130 890 44 170 875 44 210 860 45 240 820 47 280 HIGH OFF OFF CFM TEMP.
*UD2C080A9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 782 49 75 762 51 110 751 51 145 748 51 185 737 52 225 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 870 44 90 865 45 125 861 45 175 848 45 215 831 46 255 HIGH OFF OFF CFM TEMP.
*UD2C080B9V4VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 974 49 133 968 49 285 949 50 202 925 51 254 906 52 304 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1102 43 93 1112 43 144 1103 43 201 1083 44 255 1066 45 305 HIGH OFF OFF CFM TEMP.
*UD2B100A9V3VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 751 64 86 796 61 132 817 59 175 832 58 218 838 57 263 OFF CFM TEMP. RISE WATTS 862 56 121 921 52 185 953 51 233 967 50 285 954 50 322 OFF OFF CFM TEMP.
*UD2C100A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 900 53 100 890 54 130 870 55 175 850 57 220 835 58 270 OFF CFM TEMP. RISE WATTS 1125 43 150 1090 44 200 1060 46 235 1070 45 300 1070 45 340 OFF OFF CFM TEMP.
*UD2C100B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 953 50 93 944 50 146 936 51 193 908 52 243 887 54 292 OFF CFM TEMP. RISE WATTS 1142 42 135 1141 42 200 1135 42 255 1112 43 322 1098 43 377 OFF OFF CFM TEMP.
*UD2D120A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW7 SW8 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 1007 57 114 1062 54 177 1084 53 285 1063 54 303 1063 54 350 OFF CFM TEMP. RISE WATTS 1154 50 167 1211 48 230 1211 48 277 1221 47 344 1212 48 417 OFF OFF CFM TEMP.
*UD2D120B9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING S4-3 S4-4 LOW ON ON MEDIUM ** ON HIGH EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM TEMP. RISE WATTS 1050 45 99 1044 46 146 1035 46 208 1005 47 252 980 48 310 OFF CFM TEMP. RISE WATTS 1214 39 129 1216 39 188 1217 39 262 1192 40 252 1169 41 310 OFF OFF CFM TEMP.
*UD2D140A9V5VB FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 EXTERNAL STATIC PRESSURE SW 8 0.1 0.3 0.5 0.7 0.9 1090 62 130 1100 61 175 1070 63 215 1080 62 255 1060 63 290 LOW ON ON CFM TEMP. RISE WATTS MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1230 55 180 1265 53 235 1280 53 315 1300 52 380 1300 52 455 HIGH OFF OFF CFM TEMP.
PRODUCT DATA WIRING DIAGRAM From Dwg.
PRODUCT DATA SCHEMATIC DIAGRAMS From Dwg.
PRODUCT DATA FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES M SEE HUM SEE NOTE 5 EAC SEE NOE TEE 5 S From Dwg. 21B341127 Rev. 0 FIELD WIRING DIAGRAM FOR TWO STAGE HEATING TO 115 V 1 PH., 60 HZ., POWER M SYEE EPERE SUPPL LOCAL CODES TE 5 HUM SEE NOTE 5 CEASC SEE EE NOTE 5 TE 5 From Dwg. 21B341126 Rev.
PRODUCT DATA FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341125 Rev. 1 FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg. 21B341124 Rev.
PRODUCT DATA FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., WER S60 EHZ., EE E YPOPER SUPPL LOCAL CODES 5 HUM SEE W ER R6 6 NOTE 5 DEAEC S SEEL NOTE 5 From Dwg. 21B341128 Rev.
DATA SUBJECT TO CHANGE WITHOUT NOTICE 13-1/16" 15-5/16" 24-1/2" 9-5/8" B 21" 17-1/2" A * - First Letter May Be "A" or "T" ** - Suffix Letters May Be "K" (0 Through 9) *UD2C080A9V4V** *UD2C100A9V5V** *UD2C080B9V4V** *UD2C100B9V5V** *UD2D120A9V5V** *UD2D140A9V5V** *UD2D120B9V5V** *UD2B060A9V3V** *UD2B080A9V3V** *UD2B100A9V3V** MODEL (ALL DIMENSIONS ARE IN INCHES) C 23-1/4" 19-3/4" 16-1/4" TUD-9V OUTLINE DRAWING 23" 19-1/2" 16" D From Dwg.
22-1650-13 DATA SUBJECT TO CHANGE WITHOUT NOTICE 25
PRODUCT DATA Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change the design and specifications without notice. Technical Literature - Printed in U.S.A.