75 1.1 11.4 9.3 0.61 58.5 1.8
75 1.5 11.9 9.8 0.62 62.0 3.1
75 1.8 12.2 10.0 0.62 63.9 4.2
75 2.1 12.4 10.2 0.63 65.3 5.5
75 2.3 12.5 10.3 0.63 65.8 6.2
75 2.4 12.5 10.4 0.63 66.4 7.0
75 2.6 12.6 10.5 0.63 67.0 8.2
77 1.1 11.6 9.5 0.62 60.1 1.8
77 1.5 12.1 10.0 0.62 63.7 3.0
77 1.8 12.4 10.3 0.63 65.6 4.2
77 2.1 12.6 10.5 0.63 67.0 5.5
77 2.3 12.7 10.5 0.63 67.6 6.2
77 2.4 12.8 10.6 0.63 68.2 6.9
77 2.6 12.9 10.7 0.63 68.9 8.1
86 1.1 12.7 10.5 0.63 67.3 1.8
86 1.5 13.3 11.1 0.64 71.3 3.0
86 1.8 13.5 11.3 0.65 73.4 4.1
86 2.1 13.8 11.6 0.65 75.0 5.3
86 2.3 13.8 11.6 0.65 75.7 6.0
86 2.4 14.0 11.7 0.66 76.2 6.7
86 2.6 14.0 11.8 0.65 77.0 7.9
Notes: Heating performance data is tabulated at 68°F DB entering air at AHRI/ISO 13256-1 rated cfm. See Performance correction tables to correct
performance at conditions other than those tabulated. Interpolation of data is permissible, extrapolation is not. Rated GPM 2.1; Minimum cfm
272; Rated cfm 340; Maximum cfm 408.
Table 7. GET 012 cooling performance
EWT GPM
Total Gross
(Mbtuh)
Gross Sen
(Mbtuh) SHR
Heat of Rej
(Mbtuh)
Comp Pwr
(kW) LWT
WPD
(feet head)
45 1.5 13.1 10.3 0.78 14.7 0.45 64.6 4.9
45 2.0 13.2 10.3 0.78 14.7 0.43 59.7 8.1
45 2.4 13.2 10.3 0.78 14.7 0.42 57.2 11.2
45 2.8 13.3 10.3 0.78 14.7 0.41 55.5 14.6
45 3.0 13.3 10.3 0.78 14.7 0.41 54.8 16.5
45 3.2 13.3 10.3 0.78 14.7 0.41 54.2 18.4
45 3.5 13.3 10.3 0.78 14.7 0.41 53.4 21.5
55 1.5 13.0 10.2 0.79 14.8 0.52 74.7 4.7
55 2.0 13.1 10.2 0.78 14.7 0.49 69.7 7.8
55 2.4 13.1 10.2 0.78 14.7 0.48 67.3 10.7
55 2.8 13.1 10.2 0.78 14.7 0.47 65.5 14.1
55 3.0 13.1 10.2 0.78 14.7 0.46 64.8 15.9
55 3.2 13.1 10.3 0.78 14.7 0.46 64.2 17.8
55 3.5 13.1 10.3 0.78 14.7 0.46 63.4 20.7
68 1.5 12.7 10.1 0.79 14.8 0.62 87.7 4.5
68 2.0 12.8 10.1 0.79 14.8 0.59 82.8 7.4
68 2.4 12.8 10.1 0.79 14.7 0.57 80.3 10.2
Table 6. GET 009 heating performance (continued)
EWT GPM
Total Gross
(Mbtuh)
Heat of Absorb
(Mbtuh)
Compr Power
(kW) LWT
WPD
(feet head)