Wireless Ethernet Bridge User Manual
Getting Started Troubleshooting Ethernet Connections
Trango Broadband Wireless — Atlas5010 page 12
Troubleshooting Ethernet Connections
If you cannot telnet into th e radio or open an HTTP brow ser session, check your cable co nnections to ensure prop er use
of cross-over vs. straight-through cable, and ensure your PC’s su bnet is routable to the radio’s IP address.
System Information (sysinfo) Page
To display system configuration and status information type the command sysinfo.
The sysinfo screen is divided into 7 sections (0 –7)
Section Description
0 Hardware/Firmware versions & system uptime (since reboot)
1 Mac, serial number, and IP configuration information
2 Opmode, RF info, speed, and peer connection status
3 RF channel table
4 Area code information denotes which channels and power limits are available based on region
code of the radio. Area code is set by the factory an d can not be altered by the user.
5 ARQ status, encryption, Auto-rate shif t, remarks, and LED RSSI function
6 Ethernet TX/RX statistics.