User Manual

HTTP Browser Interface HTTP Browser Interface
Trango Broadband Wireless — Access5830 User Manual Rev. H 3.0 page 51
AP Configuration
Note: Some of the parameters below will be unavailable (grayed out) if the radio is in Opmode "AP." Remember to Save and
Activate Settings.
Base ID: Arbitrary integer 1-
127. All SUs that wish to
communicate with the Base
station must have same Base ID
loaded into their memory. It
can only be changed while in
Opmode “OFF.”
AP ID: Arbitrary integer 1-255.
For identifying APs within a
single Base station. It can only
be changed while in Opmode
“OFF.”
IP Address: The IP address of
the AP for use in Telnet, HTTP,
SNMP, and TFTP.
Default Opmode: Is the
Opmode, after a reboot or
power cycle, that the radio will
enter after the period of time
determined by the Default
Opmode parameter. Provided
that no attempt to connect via
serial port or Telnet is made.
Switches: Checked means
active.
Block Broadcast and
multicast packets: Block these
types of Ethernet packets when
active. ARP packet will be
passed.
Activate SU to SU communication: Allows SUs in matching groups (except group 0) to communicate with each other via the
AP. See the Subscriber Database section for more information.
Broadcast time stamp to SU: Sends a copy of the real time clock to the SU every 60 seconds. May be used for tracking
statistics when using SNMP.
Active Channel/Polarization: The current channel and antenna polarization being used in the sector when Opmode is "AP."
SUs in this sector must have these values loaded in their AP Scan sequence.
Remarks: A text field available for system administrator’s general use. Does not affect system performance.
Save and Activate Settings: Saves the variables to FLASH memory and activates setting.
Add Subscriber: Links to Subscriber Database
page to enter new subscriber.
Activate Opmode: Turns Opmode to “AP,” to turn the Opmode to “OFF,” see Default Opmode.
Reboot System: Reboots the system. Make sure all settings have been saved first.