Datasheet
Bus Operating Conditions
General
Parameter
Symbol
Min.
Max.
Unit
Remark
Peak voltage on all lines
-0.3
V
DD
+0.3
V
All Inputs
Input Leakage Current
-10
10
µA
All Outputs
Output Leakage Current
-10
10
µA
Power Supply Voltage
Parameter
Symbol
Min.
Max.
Unit
Remark
Supply voltage
V
DD
2.7
3.6
V
Output High Voltage
V
OH
0.75* V
DD
V
I
OH
=-100uA@V
DD
Min.
Output Low Voltage
V
OL
0.125* V
DD
V
I
OL
=100uA@V
DD
Min.
Input High Voltage
V
IH
0.625* V
DD
V
DD
+0.3
V
Input Low Voltage
V
IL
V
SS
-0.3
0.25* V
DD
V
Power up time
250
ms
From 0v to V
DD
Min.
Current Consumption
The current consumption is measured by averaging over 1 second.
• Before first command: Maximum 15 mA
• During initialization: Maximum 100 mA
• Operation in Default Mode: Maximum 100 mA
• Operation in High Speed Mode: Maximum 200 mA
• Operation with other functions: Maximum 500 mA