Data Sheet
9
2.6 Environment Specifications
[Table 6] Environment Specification
Features
Operating
1)
Non-Operating
2)
Temperature
-40°C to +85°C
-40°C to 85°C
Temperature Gradient
60°C/Hr
60°C/Hr
Humidity
5% to 95%, non-condensing
Shock
1500G, duration 0.5 ms, 3 axis
3)
Vibration
20G, 7~2000Hz, 3 axis
4)
Note:
1) The operating specification is regarded as Ambient Temperature. Standard grade (0°C to +70°C) and Industrial grade (-40°C to
+85°C) indicate the temperature conditions for testing devices on programmable temperature and humidity chamber room.
2) The non-operating specification is regarded as storage specification.
3) Refer IEC 68-2-27 standard.
4) Refer IEC 68-2-6 standard.
Recommended Measurement Point
Recommended temperature measurement point is in the center of the connector inserted by the device. Sufficient airflow is
recommended for proper operation on heavier workloads within the device operating temperature.
2.7 System Reliability
[Table 7] Telcordia SR-332 issue 4 MTBF Specifications
Parameter
16GB
32GB
64GB
128GB
256GB
512GB
1TB
MTBF
2,500,000 hours
Note:
1) The calculation is based on 25°C.