6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki LMU-2000 Hardware & Installation Guide Contents 1 Introduction 1.1 About This Manual 1.2 About The Reader 1.3 About CalAmp 1.4 About the CalAmp Location Messaging Unit-LMU-2000™ 2 System Overview 2.1 Overview 2.2 Component Descriptions 2.2.1 Wireless Data Network 2.2.2 LMU-2000™ 2.2.3 LM Direct™ Server 2.2.4 Backend Software 2.2.5 PULS™ 2.2.6 LMU Manager™ 3 Hardware Overview 3.1 Location Messaging Unit-LMU-2000™ 3.1.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki 5.3.1 Comm Verification 5.3.2 GPS Verification 5.3.3 Inbound Verification 5.3.4 Verification via SMS 6 License Agreement 7 Limited Warranty 8 Regulatory Information LMU-2000™ Hardware and Installation Guide IMPORTANT: DO NOT INSTALL OR USE THE SOFTWARE OR DOCUMENTATION UNTIL YOU HAVE READ AND AGREED TO THE LICENSE AGREEMENT AND REVIEWED THE LIMITED WARRANTY AND REGULATORY INFORMATION.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki This includes a description of roles and responsibilities of each of the CalAmp components as well as a brief overview of the wireless data technologies used by the LMU-2000™. Hardware Overview – Describes the physical characteristics and interfaces of the LMU2000™. Installation and Verification – Provides guidance for the installation of the LMU-2000™ in a vehicle and instructions on how to verify the installation is performing adequately. 1.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki preprogrammed before shipment or in the field. Combining affordability and device intelligence with your unique application can give you distinct advantages over your competition. Over-the-Air Serviceability The LMU-2000™ also incorporates CalAmp's industry leading over-the-air device management and maintenance system software, PULS™ (Programming, Updates, and Logistics System).
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki Basic System Architecture 2.2 Component Descriptions 2.2.1 Wireless Data Network The Wireless Data Network provides the information bridge between the LM Direct™ server and the LMU2000™. Wireless data networks can take a variety of forms, such as cellular networks, satellite systems or local area networks. Contact the CalAmp sales team for the networks available to the LMU-2000™. 2.2.
/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki A location or status request from the LM Direct™ server A location or status request from LMU Manager An SMS request made from a mobile device such as a customer’s cell-phone In some cases, it is necessary to run an application in the vehicle while it is being tracked by the backend software. Such examples could include instant messaging between vehicles or a central office, in-vehicle mapping or driving directions, email or database access.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki LMU-2000™ or making a request forwarded by the LM Direct™ server. For further details on using LMU Manager, please refer to the LMU Manager Users Guide. 3 Hardware Overview 3.1 Location Messaging Unit-LMU-2000™ 3.1.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki Packaging Anytime the sub assembly is shipped and it is not fully packaged in its final housing it must be sealed in an ESD safe bag. Electrical Over-Stress (EOS) The GPS receiver can be damaged if exposed to an RF level that exceeds its maximum input rating. Such exposure can happen if a nearby source transmits an RF signal at sufficiently high level to cause damage.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki Weight 1.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki 2m CEP (with SBAS) -162 dBm tracking sensitivity Communications (Comm) Quad Band Class 12 GPRS Modem 850 MHz (Class 4) – 2W 900 MHz (Class 4) – 2W 1800 MHz (Class 1) – 1W 1900 MHz (Class 1) -1 W GPRS Packet Data (UDP) SMS RoHS Compliant 3.2 LMU-2000™ Connectors 3.2.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki Pin Signal Name Description 2 Bus+ Line 4 Chassis Ground Ground 5 Signal Ground Ground 6 Can High ISO 15765-4 and SAE-J2284 7 K line ISO 9141-2 and ISO 14230-4 10 Bus- Line SAE-J1850 PWM and SAE-1850 VPW 14 Can Low ISO 15765-4 and SAE-J2284 (Not supported for the LMU-2000) 15 L line 16 Battery Power SAE-J1850 PWM and SAE-1850 VPW ISO 9141-2 and ISO 14230-4 Power 3.2.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki 3.3 I/O Descriptions The LMU-2000™ provides the following Inputs for scripting purposes, but there are no selectable inputs on the device Digital Inputs Input 0: Engine-On Input 1: Motion Sensor (low = no motion, high = motion) Input 2: Power State Input 3: Battery Voltage Low Analog to Digital Inputs A/D 0: Vin A/D 1: uP Temp A/D 2: Vref 3.3.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki Condition LED 2 GPS Off Off GPS On Slow Blinking GPS Time Sync Fast Blinking GPS Fix Solid 4 Configuration and Activation This section details how to quickly get an LMU-2000™ provisioned and configured to point at a specific server. It is assumed that a PEG script has already been created and is being managed through LMU Manager or PULS™, the CalAmp Maintenance System.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki 4. Alternatively if a URL has been set up for your LM Direct™ server, the LMU may be programmed with: AT$APP PARAM 2319,0,myURL.MyCompany.Com Where myURL.MyCompany.com is the URL assigned to the server. 5. Enter ATIC to verify the correct settings are displayed for your Inbound Server. This configuration process is accomplished via a series of SMS Commands: 1. Power up the LMU-2000™ and your handset 2.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki SIM the APN, username and password will switch to the new SIM card's defaults if the MCC and MNC values change. The current list of supported MCC and MNC combinations are: AT&T – formerly AT&T Wireless or Cingular Blue (MCC 310, MNC 38) o APN 0: PROXY o APN 1: PUBLIC AT&T – formerly Cingular Wireless (MCC 310, MNC 17, 18, 41) o APN 0 & 1: ISP.CINGULAR o Username: ISP@CINGULARGPRS.COM o Password: CINGULAR1 Manxpronto (MCC 234, MCN 058) o APN web.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki TelCel Mexico (MCC 334 MNC 02) o APN 0 & 1: INTERNET.ITELCEL.COM o Username: webgprs o Password: webgprs2002 Telstra Australia (MCC 505, MNC 01, 11, 71, 72) o APN 0 & 1: telstra.internet Vodafone Ireland (MCC 272, MNC 01) o APN 0 & 1: isp.vodafone.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki Check with the CalAmp Sales team for availability of the LMU-2000™ with GSM or HSPA modems. For a GSM/GPRS operator you will get the LMU in one of two varieties, one with a SIM and one without. If you get an LMU without a SIM (which is the typical case) the operator will simply ask for the IMEI of the LMU. The IMEI (International Mobile Equipment Identifier) is printed on the bottom of the LMU under the LMU’s ESN.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki Only enter this next command if you have been given a non-zero PIN as any errors may lock you out of the modem. AT$APP PIN You can confirm activation by watching the Comm LED to see if it goes solid.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki 2. Remove the top-plate to expose the top-side of the LMU-2000™’s main-board. 3. Align the SIM so the contacts are facing up and the notch is facing into the LMU-2000™ 4. Insert the SIM into the LMU. 5. Snap the LMU-2000™’s cover back in place. 4.5 Activating a CDMA LMU-2000™ Check with the CalAmp Sales team for availability of the LMU-2000™ with CDMA modems.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki What you should get back will vary from operator to operator; however at very least it will be the MDN (Mobile Directory Number) and MIN (Mobile Information Number). You should also ask for the SPC (Service Programming Code) in case it is not 000000. The SPC is effectively a password to the modem which allows you to program some of the more sensitive items (ex: the MDN and MIN). Please note that the MIN and MSID can be the same value. 4.5.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki AT$APP MODEM UPDATE This command is also used to initiate an Over-The-Air PRL Update for devices that are already provisioned. Users may also force a reactivation with the command: AT$APP MODEM ACTIVATE Keep in mind, however, this may cause the modem to lose its credentials and become unable to register to the network. 4.5.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki The Phone Number field should match the value you used in step 3 or 4. The last 10 digits of the IMSI field should match the value you used in step 3 or 4. 5 Installing the LMU 5.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki 5.3.1 Comm Verification Installers should first verify that the LMU-2000™ has been acquired and has registered to the wireless network. This may be verified in one of two ways. First, installers may look at the Comm LED (i.e., the one closest to the SMC antenna connector). If this LED is solid, then the LMU has registered to the network and established a data session.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki The next step is to verify that the GPS receiver is seeing enough satellites to obtain a valid GPS position. Again, installers have two choices on how to perform this verification. First, like the Comm Verification, there is a GPS status LED (i.e., the one closest to the SMA connector). If this LED is solid, then the LMU has found GPS service.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki The installer will need to verify with a backend technician that the, URL (myURL.myCompany.com ), IP address (ddd.ddd.ddd.ddd) and port () are correct. The second step is to verify that the LMU-2000™ is sending data. The best way to do this is to force the LMU-2000™ to send in an unacknowledged Event Report (i.e.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki The current firmware version in use by the LMU COM: o : This is the signal strength the wireless modem sees from the network. In general the LMU is at least scanning for the network if the RSSI is not -113. o [./d/D]: If the character ‘D’ is present, it indicates the LMU had a data session established when it responded to the status request.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki receiver is off. o [No Time Sync]: If this field is present, it indicates that the LMU’s GPS receiver has not been able to find even a single GPS satellite. This would likely been seen in conjunction with the above antenna error, or if the LMU GPS antenna is otherwise blocked. o [ ]: If these fields are present it indicates that the LMU has, or had a valid GPS solution.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki should match UDP port you are using on your LM Direct™ server. It is typically 20500. o : This is the current UDP/IP messaging protocol in use by the LMU. In general it should be LMD. Example GSM Response APP:081 8.3d COM:0 GPS:No Time Sync INP:11100111 13.7V MID:4141000100 ESN INB:207.7.101.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki backups, updates, merged or partial copies permitted hereunder or subsequently provided to you. “Related Materials” means all other materials and whatever is provided by or from CalAmp, and the non-Software and non-Documentation contained on the media supplied, downloaded, or otherwise supplied by or from CalAmp for use with the Software and Documentation.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki use, reproduction, distribution or publication. All rights not specifically granted in this License are reserved by CalAmp. Customer agrees to include the notice “Copyright © 1999 – 2009 CalAmp DataCom Inc., All Rights Reserved” in Applications developed with the Software. Customer agrees to include the following CalAmp Copyright and Government Restricted Use notice in all documentation and in any Application on-line help or readme file.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki comparable license has been purchased for the Software as evidenced by a CalAmp License Certificate.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki use and service FOR A PERIOD OF NINETY (90) DAYS FROM THE DATE OF DEVELOPER LICENSE PURCHASE. CalAmp’s entire liability and your exclusive remedy as to defective media, Documentation or Related Material(s) shall be replacement of the media, Documentation or Related Material(s) by CalAmp. Each defective item, along with proof of license purchase and date, must be sent in a traceable manner to: CalAmp DataCom Inc., 1401 North Rice Ave.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki superseded purchase order terms and conditions shall be null and void; (4) You agree to assure that copies of this License Agreement are distributed, read and agreed to by each Developer using the Software and/or Documentation.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki To ensure that the LMU-2000™ complies with current FCC regulations limiting both maximum RF output power and human exposure to radio frequency radiation, a separation distance of at least 20 cm must be maintained between the unit’s antenna and the body of the user and any nearby persons at all times and in all applications and uses. Additionally, in mobile applications, maximum antenna gain must not exceed 3.2 dBi.
6/20/2014 LMU-2000 Hardware & Installation Guide - PULS Wiki The equipment should only be used where there is normally at least 20cm separation between the antenna and all person/user. This transmitter must not be co-located or operation in conjunction with any other antenna or transmitter. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. https://puls.calamp.