Contents 1 2 3 Description Model IN4000 1 About Ptec™ Technology 1 Features 1 Power Requirements 2 Operation and Use Environmental Conditions 2 Set-up and Placement 2 Mounting 3 Power and Gas Connection 3 Maintenance Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replacement 5 Service 6 Troubleshooting 6 4 Specifications 7 5 Service and Warranty 8 6 IN4000 Line Drawing 9
Description Ionizing Air Nozzle Model IN4000 The IN4000 Airflex ionizer combines exceptionally fast static decay capability with excellent balance stability, all in a small footprint. Designed to protect most static sensitive devices, the IN4000 uses a specialized piezoceramic technology that makes all the Ptec™ ionizers so reliable. The height and angle of the nozzle can be easily adjusted with a metal snake shape tube ,which is very convenient to operate.
Features cont’d. Small ,light design in shape. No extra power unit is needed. The device incorporates with an ultra-small HV power unit. It has no HV wiring, so it is safe and convenient to operate. The height and angle of the nozzle can be easily adjusted. The foot switch can control both electric power and air supply. It is equipped with an ionization indicator light (green) and an abnormal HV indicator light (red). The device is equipped with auto ion balance.
Power and Gas Connection Connect the foot switch to the base of the ionizer. Attach the IN4000 to the gas line using the appropriate tubing. The IN4000 comes with a 1/4” quick release connector. Adjust pressure as required. Connect the power cord to its corresponding inlet on the base of the ionizer. Make certain the unit is grounded. Turn the unit on with the red “On - OFF” button. Operation Press the foot switch to creates a stream of positive and negative air ions.
Alarm The device is equipped with abnormal HV alarm. The red alarm indicator light illuminates when the following situations occur: 1. Low output HV 2. Short circuit 3. Abnormal HV discharge 4. Wet air flow 5. Frequent turning on and off of the photoelectric switch in a short time. Caution ! The only serviceable parts inside the ionizer are the replaceable emitter points. Any unauthorized service will void the warranty and may result in additional repair fees.
Periodic Maintenance The only regular maintenance required for the IN4000 is the periodic cleaning of the emitter point. Emitter point cleaning affects the static decay ability of the ionizer and is important for maintaining its optimal performance. Cleaning the emitter points Contaminants will gradually accumulate on the tip of the emitter points with continuous use. Periodic cleaning of the emitter points is necessary to maintain the performance of the ionizer.
Because the IN4000 high voltage output is AC, emitter erosion from the ionization process on the electrodes is minimal. Unless physically broken or stressed, the IN4000 emitters should last the life of the ionizer. Follow these instructions to remove the emitter points: 1. 2. 3. 4. Turn off and disconnect the unit from the AC power. Remove the output nozzle. Unscrew the emitter point using needle nose pliers. Replace and tighten the new emitter using the same tool. Do not over-tighten. 5.
Specifications Power supply volt AC 100V~240V 50/60Hz Output HV AC2200V Safety Performance Abnormal HV Alarm Tempreture Range 0~40℃ Air Pressure Range 28-100(psi) Ozone Density Less than 0.01ppm Ion Balance 0±30V Indicators ON/OFF: red LED, POWER: green LED On/Off button Controls Certifications Caution ! When adjusting the angle the IN4000 nozzle, grip the metal snake neck only. DO NOT grip the plastic nozzle. Using the plastic nozzle to adjust angle may cause physical or internal damage.
Service and Warranty Transforming Technologies, LLC provides a limited warranty for the Model IN4000 ionizing air nozzle. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident.
IN4000 Line Drawing ⑨ ⑧ 2 13 146 ⑦ 50 ② 70 100 185 ① ③ ON£ -OFF POWER ④ 185 ⑤ ①Nozzle ②Snake shape tube ③Base ④LED(Green) ⑤Alarming LED(Red) ⑥Power switch ⑦Foot switch outlet ⑧Power cord outlet(Including fuse) 9 ALARM ⑥