TRANSFORMING TECHNOLOGIES, LLC O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ptec™ Static Eliminators Benchtop Blower Model IN5120 Instruction Manual
Contents 1 2 3 Description Model IN5120 1 About Ptec™ Technology 1 Features 1 Power Requirements 2 Operation and Use Environmental Conditions 2 Set-up and Placement 3 Power Connection 3 Maintenance Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replacement 5 Bracket Removal 6 Service 6 Troubleshooting 6 4 Specifications 7 5 Service and Warranty 8 6 IN5120 Line Drawing 9
Description In-tool Ionizing Blower Model IN5120 The Model IN5120 68KHz AC in-tool air ionizer is a small, efficient static elimination device with variable fan speed for protecting electronic components and general static protection. Using AC corona technology, to make the air more conductive, Ptec™ ionizers produce a balanced stream of positive and negative air ions that never need calibration. These devices are used in many industries and manufacturing applications where static electricity is a problem.
The rear panel of the ionizer has the 24 VDC power input connector and a grounding point. Physically small and light. Rapidly decays static charges. Excellent ion balance and ionization performance. Ionization (green) and HV alarm (red) lights. No periodic adjustments. Durable, replaceable tungsten alloy emitter points. Removable front grill. Adjustable air volume.
Set-up and Placement Caution ! Do not use this ionizer in an explosive environment! Corona ionizers produce a weak plasma that can cause ignition in explosive environments. Use the IN5120 in-tool ionizing blower in proximity to a static sensitive area or object. The unit can be set on the workstation or mounted to a structure, using the ushaped mounting bracket and hardware. Point the unit at the area to be protected.
Maintenance Periodic Maintenance Caution ! The only serviceable parts inside the ionizer are the replaceable emitter points. Any unauthorized service will void the warranty and may result in additional repair fees. The only regular maintenance required for the IN5120 is the periodic cleaning of the emitter points and ionizer grill. Emitter point cleaning affects the static decay ability of the ionizer and is important for maintaining its optimal performance.
Follow these instructions to clean the emitter points: 1. Remove the front grill. 2. Moisten a swab or wiping cloth in the IPA solution. 3. Swab or wipe the emitter points until they are free of particles. 4. Make certain the emitter points are straight and parallel to the plane of the fan. 5. Replace the front grill. 6. Make sure the emitter points are dry before powering the ionizer again. Emitter Point Replacement The IN5120 uses 10 tungsten alloy precision etched emitter needles.
6. Make certain the emitter points are straight and parallel to the plane of the fan. 7. Replace the front grill. Bracket Removal The IN5120 in-tool ionizing blower can be removed from the universal bracket by unscrewing the side knobs. Note that there are washers located between the side knobs, stand and chassis. Service Ptec™ ionizers are reliable products with a long service life. If you feel your unit is not operating properly, turn off the unit and disconnect the power cord.
Specifications Power input 24 VDC, 12W Power outlet unfused, 0.5A or 1.0A max. Ion Emission AC, 68KHz Balance +/- 5 volts, typical offset Decay Time 1000V - 100V < 3 seconds at 1 foot Temperature 66-78°F (19-25°C) Humidity 20-60% RH (non-condensing) Airflow 49 CFM, typical, high speed Noise level 35dB(A) (Distance 1 meter) Indicators Power: green LED Controls On/Off slide switch, fan speed control Emitter points .036" dia. Tungsten alloy, etched Ozone <0.
Service and Warranty Transforming Technologies, LLC provides a limited warranty for the Model IN5120 benchtop blower. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident.
IN5120 Line Drawing 9
TR A N S F OR MI N G T EC H N OL OGI ES, L LC 3719 King Rd. Toledo, Ohio 43617 Phone: 419-841-9552 Fax: 419-841-3241 E-mail: info@transforming-technologies.