TRANSFORMING TECHNOLOGIES, LLC O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ptec™ Static Eliminators Overhead Ionizing Blower Model IN5130 Instruction Manual
Contents 1 2 3 Description Model IN5130 1 About Ptec™ Technology 1 Features 1 Power Requirements 2 Operation and Use Environmental Conditions 2 Set-up and Placement 2 Mounting 3 Power Connection 3 Maintenance Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replacement 5 Service 6 Troubleshooting 6 4 Specifications 7 5 Service and Warranty 8 6 IN5130 Line Drawing 9
Description Overhead Blower Model IN5130 The Model IN5130 68KHz AC overhead air ionizer is designed to cover a complete workstation and to protect sensitive electronic components from damage due to electrostatic discharge (ESD). Using AC corona technology to make the air more conductive, Ptec™ ionizers produce a balanced stream of positive and negative air ions that never need calibration. These devices are used in many industries and manufacturing applications where static electricity is a problem.
Features cont’d. Complete workstation protection. Rapidly decays static charges. (1KV to 100V, < 6 sec. @ 24”). Excellent ion balance, 0 +10V. Stable AC technology. Ionization indicator light. HV alarm (red) lights. No periodic adjustments. Durable, replaceable tungsten alloy emitter points. Removable front grill. Adjustable air volume.
Use the IN5130 overhead blower in proximity to a static sensitive area or object. The unit can be mounted on the workstation or attached to a structure using the mounting holes provided. Caution ! Do not use this ionizer in an explosive environment! Corona ionizers produce a weak plasma that can cause ignition in explosive environments. Mounting Install the overhead ionizer 24” (60.9 cm) above the work area to achieve the most uniform decay performance.
The red alarm indicator light illuminates in the event of a problem with the high voltage power output. Turn the power switch off after operation. Maintenance Caution ! The only serviceable parts inside the ionizer are the replaceable emitter points. Any unauthorized service will void the warranty and may result in additional repair fees. Periodic Maintenance The only regular maintenance required for the IN5130 is the periodic cleaning of the emitter points and ionizer grills.
Follow these instructions to clean the emitter points: 1. Remove the front grill. 2. Moisten a swab or wiping cloth in the IPA solution. 3. Swab or wipe the emitter points until they are free of particles. 4. Make certain the emitter points are straight and parallel to the plane of the fan. 5. Replace the front grill. 6. Make sure the emitter points are dry before powering the ionizer again. Emitter Point Replacement The IN5130 uses tungsten alloy precision etched emitter needles.
6. Make certain the emitter points are straight and parallel to the plane of the fan. 7. Replace the front grill. Service Ptec™ ionizers are reliable products with a long service life. If you feel your unit is not operating properly, turn off the unit and disconnect the power cord. Contact Transforming Technologies’ Technical Support for repair assistance. Troubleshooting The information below provides a reference for problems that may arise with your IN5130 overhead blower.
Specifications Power input 100-240VAC, 50/60 Hz, 36W Power outlet Un-fused, 0.5A or 1.0A max. Ion Emission AC, 68KHz Balance +/- 10 volts, typical offset Decay Time 1000V - 100V < 6 seconds at 24" Temperature 66-78°F (19-25°C) Humidity 20-60% RH (non-condensing) Airflow 115 x 3 CFM, typical, high speed Noise level 60dB(A) (Distance 1 meter) Indicators Power: green LED Controls On/Off rocker switch, fan speed knob Emitter points .036" dia. Tungsten alloy, etched Ozone <0.
Service and Warranty Transforming Technologies, LLC provides a limited warranty for the Model IN5130 overhead blower. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Transforming Technologies. The company does not warrant damage due to misuse, neglect, alteration or accident.
IN5130 Line Drawing 9