Cable Box User Manual

CFETF10xx-205
14
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting the 4-position switch and the jumpers. Failure to
observe this caution could result in damage to, and subsequent failure of, the
media converter.
Set the 4-Position Switch
The 4-position switch is
located on the circuit board.
Use a small flat-blade
screwdriver to set the
recessed switches.
1. Auto-Negotiation
up = Advertises 100 Mb/s Full-Duplex and Half-Duplex (only during
Auto-Negotiation).
down = Disables Auto-Negotiation. Operates at 100 Mb/s in the mode
(either full- or half-duplex) of the attached device.
2. Pause
(Applies ONLY if switch “1” is up AND the media converter is connected
to auto negotiating device(s) capable of Pause Control Frame.)
up = Allows negotiation of Pause Control Frame.
down = Does not allow negotiation of Pause Control Frame.
3. Link Pass-Through
up = Enables Link Pass-Through.
down = Disables Link Pass-Through.
4. Far-End Fault
up = Enables Far-End Fault.
down = Disables Far-End Fault.
Set the hardware/software Jumper
The header for the jumper is located on the circuit board labeled “H”
hardware mode and “S” software mode.
Use small needle-nose pliers to remove and position the jumper.
Hardware The four DIP switches control the function
of the board in hardware mode. You can
only view status via the Web or Focal
Point interface.
Software Software controls the function of the
board. The DIP switches do not function
in software mode.
Hardware Mode
Software Mode
H
H S
S
Link Pass Through (up = enabled)
Pause (up = enabled)
Auto-Negotiation (up = enabled)
Far End Fault
(up = enabled)
1234
Contact Us
Technical Support
Technical support is available 24 hours a day.
US and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks
10900 Red Circle Drive Minnetonka, MN 55343, U.S.A.
telephone: 952-941-7600
toll free: 800-526-9267
fax: 952-941-2322
Declaration of Conformity
Name of Mfg: Transition Networks
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.
Model: CFETF10xx-205 Series Media Converters
Part Number(s): CFETF1011-205, CFETF1013-205, CFETF1014-205, CFETF1015-205,
CFETF1016-205, CFETF1017-205, CFETF1018-205, CFETF1019-205,
CFETF1039-205
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the
CFETF10xx-205
to which this declaration refers is in
conformity with the following standards.
CISPR 22: 1997+A1:2000; EN 55022:1998 A1:2000 Class A & B; EN 55024:1998; FCC
Part 15 Subpart B; EN 61000-2-3:1995 A14:2000, EN 61000-3-3:1995; 21 CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
May, 2008___
Stephen Anderson, Vice-President of Engineering Date