Installation Guide

PREPARATION
SAFETY INFORMATION
Please read and understand this entire manual and the appropriate wall panel installation manual
before attempting to install the product.
Estimated Installation Time: 60 minutes
Tools Required for Assembly (not included): Level, Shims, Drain Fitting, Silicone/ Plumber’s Putty,
Wrench, 5 Gallon Empty Bucket, Thin Set Mortar & Water, 1/4” - 1/2” Grooved Trowel.
The stud preparation is critical for the installation of the shower base. It is essential the stud pocket
be constructed square and plumb according to the roughing in information provided.
1. Please inspect the shower base for breakage and report any damage to the store of purchase.
Allow the shower base to acclimate to room temperature before installing.
2.Cleanandscrapetheooroftheshowerbasealcove.Thisspacemustbefreeofanydebrisin
order to get a proper adhesion with the thinset mortar.
3.Measurethesizeofthealcovetoinsurethatthebaseandpanelstproperly.
4.Trialtthebaseinthealcoveandmakesurethatthedrainlocationlinesupproperlywiththe
showerbase.Placingalevelonthebase,checkthatthebasesitslevelontheoor.Ifneeded,
use shims to level the base in the alcove. Note the shim locations before removing the base.
Lean the base back or remove from the alcove.
Use care when opening the box so you do not damage the shower base.
• DO NOT proceed if any doubt arises about the correct or safe method of performing anything found
in this manual. If necessary, hire or consult a trained professional for expert assistance before
continuing.
CAUTION
WARNING
1. INSTALLING THE PAN
Installthedrainttingintotheshowerpan.
Follow the installation instructions that came with
the drain. Plumber’s putty or silicone are accept
able to use with the drain.
Mixandapplythin-setmortartotheoor,usingthe
notched trowel. Spread the mixture to achieve a
depthnecessarytollthevoidsintheoorand
enable the pan to sit level. A 50 lb. bag of thin-set
should provide at least 45-50 square feet of cover
age. All supporting points should have contact with
the thin-set mortar.
1