User's Manual

EnRoute50x/51x User’s Guide
TR0153 Rev. D2
40
Figure 17. Setting the operating scheme
6.3 Mesh / Node ID
An EnRoute500 must be assigned mesh and node IDs before it is deployed as part of a mesh
cluster. Together, these values uniquely identify a node within a mesh cluster and no two
nodes in a cluster are allowed to have the same node ID.
The mesh ID must be the same for all nodes in a cluster The range of valid mesh IDs is 0
through 254.
The node ID is part of the node‟s IP address as shown in Figure 18. The allowable range for
node IDs is 1 through 254.
172.29 . 12 . 107
Mesh prefix Mesh ID Node ID
Figure 18. EnRoute500 mesh interface IP address
CLI
The mesh ID is set with the „id.mesh‟ parameter in the „sys‟ interface as shown below.
> use sys
sys> set id.mesh=12
The node ID is set with the „id.node‟ parameter in the „sys‟ interface as shown below.