User's Manual

MultiConnectHardwareInstallationGuide 1_2.doc
April 8, 2004
Page 17 of 17
Suite 230, 2891 Sunridge Way NE, Calgary Alberta, T1Y 7K7
Phone: (403) 777-3760 Fax: (403) 777-3769
MULTICONNECT TECHNICAL DATA
1 Voltage
Supply voltage 9 - 34 volts
2 Current Consumption
Standby 0.7mA
Typical
25mA
Peak
¥
3A
3 Temperature Range
Operating -30 to +60°C
-22 to +140°F
WARNING
Operation at temperatures outside this range in not recommended. Some modems
are not intended for operation at the extremes.
Storage -40 to +80°C
-40 to +176°F
4 Dimensions and Weight
Approximate Size (L x W x H) 4.75” x 5.0” x 1.0”
121 x 127 x 25 mm
Weight (with typical modem) 0.77 lbs / 0.35 kg
5 Compliance
FCC Class A Part 15
NOTE
Mentor Engineering Inc. reserves the right to change specifications without notice.
Typical Current Draw measured with device powered without a modem.
¥
Peak Current draw will vary depending on Modem type and peripheral devices used.