User's Manual

12
13.
Before exiting from the MDC Maintenance screen, the newly entered value
must be saved. To save modified parameters, select the SYS CONFIG
function key. The next screen will not display any function keys, however,
there is a save function associated with the bottom function key. Press this
key and you will be prompted to save the changed values. Press ENTER
and the values will be saved.
14.
Finally, press EXIT to leave the SYS CONFIG menu and EXIT again to
leave the maintenance menus.
Setting the MDC ID
As previously mentioned, in most systems, it is necessary to set a unique ID for each MDC
that is installed. (NOTE: For an EDACS Data Network the MDC ID must be the same
as the LID ID of the mobile radio it is connected to. When the MDC is being installed for
use on a data network such as CDPD or Mobitex, the external modem has a unique ID
and the MDC ID may require a different type of configuration. For these systems, please
refer to the appropriate applications note for the necessary set-up parameters.)
From the MDC maintenance menu, select the MDC configuration screens by pressing the
function key next to the MDC CONFIG text. From the MDC configuration screen, press
the MDC ID function key, enter the MDC ID at the prompt and press ENTER. Press
EXIT to leave the MDC configuration screen
Before exiting from the MDC Maintenance screen, the newly entered value must be saved.
To save modified parameters, select the SYS CONFIG function key. The next screen will
not display any function keys; however, there is a save function associated with the bottom
function key. Press this key and you will be prompted to save the changed values. Press
ENTER and the values will be saved.
Finally, press EXIT to leave the SYS CONFIG menu and EXIT again to leave the
maintenance menus.
Testing the Communications
As a final test, a message can be sent by the MDC to the receiving device, if one is
available. If an acknowledgement is received by the MDC, then it can be assumed that the
message made it to the receiving device, and the MDC is operating properly.
When the MDC is powered on, it usually defaults to some sort of sign-on screen. This
screen will usually have a function key labeled SIGNON. This key can be used to test
communications.