Submittal Sheet

©2016 Thermaco, Inc. • All rights reserved • Patented/Patents Pending • Specications subject to change without notice
7/16
Thermaco, Inc. • PO Box 2548 • Asheboro, NC 27204-2548 • (336) 629-4651 • www.trapzilla.com
2
Trapzilla
®
Solids Separator
A THERMACO® Technology
TSS-27 Specications
NOTES
1. READ instruction manual included with system before installing/operating.
2. Unit requires 6” (15.24 cm) of clearance all the way around the lid from walls or other structures to allow for servicing.
3. Make piping connections with rubber “No Hub” connectors.
4. Keep outlet piping as straight as possible. Use only “sweep” connections.
5. Install vent on outlet piping.
6. If installing in conjunction with other Trapzilla products, include cleanout port before, after, and/or between each unit.
7. Do not install “P” Trap on outlet connection of tank (unit already has internal gas trap).
8. Do not reduce pipe size on outlet piping
9. Do not pressure test unit.
Equipment must be installed in compliance with all applicable laws, regulations and codes, including plumbing codes. Instal-
lation should be performed by a qualied plumbing contractor.
JOB SPECIFICATION
Solids separator(s) shall be Thermaco Trapzilla solids interceptor system(s) as manufactured by Thermaco, Inc., Asheboro,
North Carolina as noted on plans.
SEPARATOR SPECIFICATIONS
Furnish and install __________ Thermaco Trapzilla Model No. TSS-27, rotationally molded polyethylene solids separator(s)
for above or below ground installation, shall be rated at 35 gpm (2.21 l/s) with 27 gallons (102 l) of total solids storage capacity,
with removable cover for solids removal access, integral anti-otation anchor ring for in-ground installation, laminar inlet ow
diverter, integral vessel vent, a unitary tank body and 3” (75 mm) inlet/outlet structures without gasket interfaces, utilizing an
interior radial compression ring conjoining invert to tank outlet/inlet structures without bulkhead ttings and/or gaskets, sloping
conical bottom, integral sewer gas trap, and a fully removable polyethylene self-positioning cover with sealed thread fasteners.
SUBMITTAL OPTIONS
ECA-TSS-29 Extension Collar
TZSP-40 Sampling Port with 4” Inlet/Outlet, 0.5” fall
TZSP-48 Sampling Port with 4” Inlet/Outlet, 7.8” fall
TZSP-40-ECA Sampling Port with 4” Inlet/Outlet, 0.5” fall and ECA-TZ-29 Extension Collar
TZSP-48-ECA Sampling Port with 4” Inlet/Outlet, 7.8” fall and ECA-TZ-29 Extension Collar
FTCA-22 Fabricated Top Cover Assembly with diamond plate aluminum surface for heavy duty foot-traffic, pallet
jacks, food carts etc. (not rated for vehicle trafc)
VFCA-35 Vented Flow Control Assembly for installation at plumbing xture level to limit ow to 35 gpm for installations with
head height greater than 6’