Installation Manual
“CH=OFF”, it means that the quantity alarm function is turned off.
To set the lower and upper count limit, press TARE key to select the hi / lo limits.
For an example, “L = 990”, press 990 on the numeric keypad, then TARE to switch
over to “H=1010”, press 1010 on the number keypad.
Press QTY/SET to confirm and return to count mode. The alarm will beep at below
990 pcs and at a different tone at 1010 pcs.
3
Ⅳ. Function setting
1. Turn off the scale.
2.
press and keep [UNIT WEIGHT] key then turn on the scale, the display will
show-----and then b=ON/OFF (beeper) on the first line, A-XX (auto off) on the
second line and L=ON/OFF (backlight) on the third line.
3.
Press [QTY/SET] to select activate or inactivate the function of the beeper.
Press [TARE] to select auto off time. Press [ZERO] key to select activate or
inactivate the function of the backlight.
4.
UNIT WEIGHT function: when there is no weight on the platform, press
[SAMPLE/UNIT] key to select the unit (kg or lb).
MEMORY STORAGE
Turn on the scale. You can either store the weight by keying in the UNIT WEIGHT
or by using SAMPLE/UNIT on the unit weights you want to save. Press STORE to
confirm the unit weight and then the display will show “c xxx” .
Press within 2 seconds, the third line of the display will show “ - - - -”.
Press [CE] to clear the memory, the second line of the display will show 0.
Press M1 to M9 to recall the unit weight from memory.
Total weight clear
1.
Press [TOTAL] to show total pieces on the third line of the display.
2.
Press [MC] to show the unit which will be cleared.
3. Press [CE] to confirm clear.
4