Manual
6
158823.02
PoE PRO
TERMINATIONS
The Dual Port Remote Unit can be stored in the bottom end of 
the Tester, with the jacks either inside for protection or outside 
for testing patch cables without removing it from the Tester, 
and provides internal storage for the Coax Remote Unit.
CONNECTIONS
To connect to a cable and to confirm correct connection:
•  Use the correct port (VOICE, VIDEO or DATA) according to 
the cable connector type. (Use VOICE for RJ11, RJ12, RJ14 
or RJ25 cables, VIDEO for F 75 Ω Coax or DATA for RJ45). 
•  Press the corresponding port button (VOICE, VIDEO or 
DATA).
•  The display shows the selected port.
•  Connect one end of the cable to the selected port on 
the tester and the other end to a Remote Unit for cable 
identification and testing or to an Identifier for cable 
identification only.
•  The display shows the type of termination (Remote Unit 
or Identifier) and its Number to assist identification when a 
number of dierent terminations are in use.
Dual Port  
Remote Unit
# 1 (Standard)
Coax  
Remote Unit 
# 1 (Standard)  
# 1 to 12 (Optional - 158053)
RJ45  
Remote Unit 
# 1 to 12 (Optional - 158050)
RJ45  
Identifier 
# 1 to 24 (Optional - 158051)
Identifier 
Indicator
Termination 
Number
Remote Unit 
Indicator
EN