Installation Instructions RD-IQL Room Display Important: Retain these instructions UNPACKING RD-IQL Installation Instructions TG200576 STORING -10 °C +14 °F +50 °C +122 °F H O 0 %RH 2 INSTALLATION 1 It is recommended that the installation should comply with the HSE Memorandum of Guidance on Electricity at Work Regulations 1989. For USA, install equipement in accordance with National Electric Code. 95 %RH For use with IQLVAV, IQL11+, 13+, 15+ controllers only Dimensions 90 mm (3.
RD-IQL Installation Instructions INSTALLATION (continued) 2 Requirements (continued) f g e d j +40 °C +122 ° F -10 °C +14 °F i h H 2 O 0 %RH 90 %RH k 3 l Check IQL+, IQLVAV Controller Compatibility Compatible with IQLVAV, IQL11+, 13+, 15+ only 4 Remove Front Panel a IQLs must have standard strategies or standard item allocations as follows: S9, S10, S1, S2, S3 (IQLVAV, IQL11+, 13+, 15+) I9 (IQL11+, 13+, 15+), I12 (IQLVAV) S11, S7 (IQL13+, 15+) IQLVAV, IQL11+ can use RD/IQL/K, /KOS
Installation Instructions RD-IQL INSTALLATION (continued) 6 Configure IQLVAV/IQL+ for use with RD a Connect Trend Tool for Text Communications See IQLTool2 See PowerTool Manual TE200163 IQL See Wupdn Manual TE200162 Lon LINC Note that a PIN may be required to make changes. If the PIN has been forgotten the users should contact their supplier (installers contact Trend Technical Support) quoting the generator number and neuron id (both from Address module) whereupon a default PIN will be supplied.
RD-IQL Installation Instructions INSTALLATION (continued) 8 Connect to IQL+ Controller L A N O /S S tra te g y : N ID D O 2 D O 1 D O 3 C O M 2 4 V ~ D O 5 D O 4 C O M 2 4 V IN 1 : IN 2 : IN 3 : : IQ L O N L + RD-IQL (rear view) 2 4 V a c C O M ~ Digital (TBus) input First digital input: IN3 for IQL11+, IN4 for IQL13+ and IQL15+ IN5 for IQLVAV polarity independent maximum distance 30m (33 yds) Note that IQL+/IQLVAV may be connected while powered; if not power up IQL+/IQLVAV.
Installation Instructions RD-IQL INSTALLATION (continued) 12 Engineer Display if required 1 a ENG + 3 2 3 S P 4 E N G b Select Temperature Units c if Temperature Units OK default = °C °F , d °C °C °F e Display Local Temperature f if Local Temperature Display OK default = , g h Use Local Thermistor Local Thermistor Use OK i default = O n WARNING: Do NOT switch off ‘Use Local Thermistor’ ! (leave at default = On).
RD-IQL Installation Instructions INSTALLATION (continued) 13 Restore Defaults if required 1 Restore Defaults a 2 3 4 ENG + 1 + 4 S P Defaults as shown in step 12 E N G b Normal Mode 6 c 14 Replace Front Panel 15 Adjust Contrast °F °F °C °C RD-IQL Installation Instructions TG200576 Issue 1/G 16/01/07
Installation Instructions RD-IQL INSTALLATION (continued) 16 Check System Dependent on option /K, /KOS, /KOSF L A N O /S S tra te g y : N ID D O 1 D O 2 D O 3 D O 5 D O 4 C O M 2 4 V ~ C O M 2 4 V IN 1 : IN 2 : IN 3 : : IQ L O N L + 2 4 V a c C O M ~ a /K, /KOS, /KOSF °C S9 °C (°F) Temp S3 Occupation, S7 Fan Speed b /K, /KOS, /KOSF °C S2 °C (°F) Setpoint c /K, /KOS, /KOSF °C S2 °C (°F) d /K, /KOS, /KOSF °C S2 °C (°F) e* /KOS, /KOSF °C S3 Occupation f /KOSF only °C
RD-IQL Installation Instructions DISPOSAL WEEE Directive : At the end of their useful life the packaging and product should be disposed of by a suitable recycling centre. Do not dispose of with normal household waste. Do not burn. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37,Switzerland by its Authorized Representative, Trend Control Systems Limited.