TRENDnet User’s Guide Cover Page
TRENDnet User’s Guide Contents Product Overview ...........................................................................1 Package Contents .......................................................................................................... 1 Features ......................................................................................................................... 1 Table of Contents Redundant Backup Setting ................................................................................
TFC-1600MM TRENDnet User’s Guide Features Product Overview The TFC1600MM module supports the management of media converters and power supplies installed in the TFC-1600 fiber chassis. This module provides instant access to cooling fan and power supply status, and allows the user to configure and monitor the state of the chassis by means of a workstation with support for SNMP, or from a PC via web browser.
TFC-1600MM TRENDnet User’s Guide Real-Time Monitoring Product Hardware Features Real-time monitoring of link, speed, and duplex status of media converters. LED Indicators LEDs convey power on/off, power fail, fan fail, MGM, console, and link/activity 10/100/1000 Mbps Gigabit Ethernet Port - To configure the device through Web Browser or TELNET program via LAN Ethernet. RJ-45 UTP console port - To configure the device through RJ-45 UTP console port.
TRENDnet User’s Guide TFC-1600MM Module Installation Installing the Management Module Install the Management Module into the Media Converter Chassis. Connect the Management Module to the network. The chassis’s first slot is for the Management Module as illustration. Slide in the management module in the first slot of the chassis system. © Copyright 2016 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide TFC-1600MM Configure your module (Web Management) This chapter provides network managers and system administrators with information about how to configure the Media Converter Chassis via the Management Module. The reader of this document should be knowledgeable about network devices, device configuration, network management, and Internet browsers. The user is assumed to be a network administrator or manager with an understanding of network operations.
TRENDnet User’s Guide TFC-1600MM Main Menu The Main Menu will show out the Hardware Revision, BIOS Revision and Firmware Revision, to set the management system, click on the left side menu, System Function and Configuration, in the center screen is the status screen that appears where you clicked on the left side menu. © Copyright 2016 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide TFC-1600MM Click on the Media Converter slot and it will appear a screen for you to monitor or control, depend on what media converter you are using. © Copyright 2016 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide TFC-1600MM System Function There are five items in System Function menu, “Software Reboot, Factory Reset, Image Update, Save Configuration and Configuration Update. Software Reboot Reboot the management module in order to run the new setting properly. © Copyright 2016 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide TFC-1600MM Factory Reset This function is to set the device back to the default setting in case of the messy setting. There are two functions in Factory Reset page: Chassis Factory Reset: for all modules factory reset. CPU Reset: only this control module factory reset. Image Update The section is to set the TFTP Server IP Address first and the Image File name as you store in the TFTP Server. The Image File can be updated by uploading the image file from the TFTP server.
TRENDnet User’s Guide TFC-1600MM Configuration Update The section is explaining how to upload and download the configure setting of the module. The Configuration Upload is to restore a setting file to the management module. The Configuration Download is to backup the setting from the management module. © Copyright 2016 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide TFC-1600MM Configuration There are five items in Configuration menu, General Configuration, System Configuration, SNMP Configuration, Location Setting and Redundant Backup Setting. General Configuration Hardware revision: noted the version of the Media Converter Chassis. BIOS revision: noted the version of the BIOS. Firmware revision: noted the version of the firmware. Old Password: the Old of the admit password. Change Password: the changing of the admit password.
TRENDnet User’s Guide TFC-1600MM System Configuration MAC Address: will show out the MAC address of the Management Module. IP Address: to allocate an IP address for the Management Module, the default IP is “192.168.1.1”. Subnet Mask: to set the Subnet Mask, the default is 255.255.255.0”. Default Gateway: to set the gateway address, the default is “0.0.0.0”. (0.0.0.0 Means no default gateway address) Note: After configuring the system device, need to press the save button to save the setting.
TRENDnet User’s Guide TFC-1600MM SNMP Configuration Get Community Name: to get the device community name (default = public). Set Community Name: to set the device community name (default = private). Trap Community Name: to authorize the device trap community name (default = public). Trap Host IP Address: to set the trap host IP address (same as monitoring station IP address). Cold Start trap: to set the trap for rebooting the device (default = disable).
TRENDnet User’s Guide TFC-1600MM Converter Location Setting Allocating each slot’s location in order to remember in where each slot was connected. Redundant Backup Setting The redundant function is to change the master line to the slave line in case of the linking fails happen. The Redundant functions were set fixed, the master slot is slot 1(odd number slot) and the slave slot is slot 2(even number slot), and there are eight redundant groups in all. The “Act” will indicate what slot is active.
TRENDnet User’s Guide TFC-1600MM Configure your Module (Command Line Interface) Console and Terminal Emulator program settings The Media Converter Chassis Management Module can be accessible using a terminal or terminal emulator attached to the RJ-45 UTP console port. Serial port configuration cable: One end of the cable is a DB9 serial port, which connects to serial port on computer. Other end is an RJ-45 UTP port, which connects to the SNMP Media Converter Chassis.
TRENDnet User’s Guide TFC-1600MM Reboot COMMANDS reboot Factory Reset COMMANDS reset cpureset reset: for all modules factory reset. cpureset: only this control module factory reset. Image Update COMMANDS update The is to set the TFTP Server IP Address first and is the Image File name as you store in the TFTP Server.
TRENDnet User’s Guide TFC-1600MM SNMP Configuration config snmp get_communityname [] config snmp set_communityname config snmp trap_communityname config snmp trap_hostip config snmp coldstart_trap {enable | disable} config snmp warmstart_trap {enable | disable} config snmp authfail_trap {enable | disable} config snmp powerfail_trap {enable | disable} COMMANDS config snmp fanfail_trap {enable | disable} config snmp mcplugin_tr
TRENDnet User’s Guide TFC-1600MM SNMP Configuration commands: config snmp get_communityname: to configure the “get” community name (default = public). config snmp set_communityname: to configure the “set” community name (default = private). config snmp trap_communityname: to configure the “trap” community name (default = public) for authorize the device trap. config snmp trap_hostip: to set the trap host IP address (same as monitoring station IP address).
TRENDnet User’s Guide TFC-1600MM CPU module information COMMANDS show mediaconverter chassis Media Converter Configuration show mediaconverter status COMMANDS config mediaconverter slot ([name ] [Device_LLCF {v|x}] [Device_Enable {v|x}] [M1_LLR {v|x}] [M1_Auto {A|F}] [M1_Speed {10M|100M|1G}] [M1_Dup {F|H}] [M1_FC {v|x}] [M1_Enable {v|x}] [M2_LLR {v|x}] [M2_Auto {A|F}] [M2_Dup {F|H}] [M2_Enable {v|x}]) Media Converter Configuration command (Some of the function can be contr
TRENDnet User’s Guide TFC-1600MM Redundant Backup Setting COMMANDS show mediaconverter redundant config mediaconverter redundantgrp ([{enable|disable}] [restart]) The redundant function is to change the master line to the slave line in case of the linking fails happen. The Redundant functions were set fixed, the master slot is slot 1(odd number slot) and the slave slot is slot 2(even number slot), and there are eight redundant groups in all. The “Act” will indicate what slot is active.
TFC-1600MM TRENDnet User’s Guide Technical Specifications Standards Converter Module Monitoring IEEE 802.3 IEEE 802.3u IEEE 802.3x IEEE 802.
TRENDnet User’s Guide TFC-1600MM MTBF 2,709,617 hours Operating Temperature 0 – 40°C (32 - 104°F) Operating Humidity Max. 90% non-condensing Dimensions 128 x 35 x 88 mm (5.04 x 1.38 x 3.46 in.) 2U height (for TRENDnet TFC-1600 chassis slot only) Weight 108 g (3.8 oz) Certifications CE FCC © Copyright 2016 TRENDnet. All Rights Reserved.
TFC-1600MM TRENDnet User’s Guide Appendix Note: If you are experiencing difficulties, please contact your computer or operating system manufacturer for assistance.
TFC-1600MM TRENDnet User’s Guide In MAC OS 10.4, from the Show drop-down list, select Built-in Ethernet and select the TCP/IP tab. In MAC OS 10.5/10.6, in the left column, select Ethernet. e. Configure TCP/IP to use a static IP. In MAC 10.4, from the Configure IPv4, drop-down list, select Manually and assign your network adapter a static IP address. Then click the Apply Now button. In MAC 10.5/10.6, from the Configure drop-down list, select Manually and assign your network adapter a static IP address .
TFC-1600MM TRENDnet User’s Guide Federal Communication Commission Interference Statement RoHS This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
TFC-1600MM TRENDnet User’s Guide Česky [Czech] Dansk [Danish] Deutsch [German] TRENDnet tímto prohlašuje, že tento TFC-1600MM je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 2011/65/EU, 2014/35/EU, 2014/30/EU, 2004/108/ES a 2006/95/ES. Undertegnede TRENDnet erklærer herved, at følgende udstyr TFC1600MM overholder de væsentlige krav og øvrige relevante krav i direktiv 2011/65/EU, 2014/35/EU, 2014/30/EU, 2004/108/EF og 2006/95/EF.
Limited Warranty TRENDnet User’s Guide Limited Warranty TRENDnet warrants only to the original purchaser of this product from a TRENDnet In the event that, after evaluation, TRENDnet cannot replace the defective product or there is no comparable model available, we will refund the depreciated value of the product. authorized reseller or distributor that this product will be free from defects in material and workmanship under normal use and service.
Limited Warranty TRENDnet User’s Guide shipping from outside of the USA and Canada are responsible for any return shipping CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, and/or customs charges, including but not limited to, duty, tax, and other fees.