Datasheet
Terminal Block
• Redundant power inputs, alarm relay contact,
6-pin
• Wire range: 0.34mm^2 to 2.5mm^2
• Solid wire (AWG): 12-24/14-22
• Stranded wire (AWG): 12-24/14-22
• Torque: 5 lb. – In / 0.5Nm / 0.56 Nm
• Wire strip length: 7-8mm
Alarm Relay Contact
• Relay outputs with current carrying capacity of
1A, 24V DC
• Open circuit mode when two power sources
are connected
• Short circuit mode when only one power
source is connected
MTBF
• 580,972 hours
Housing
• IP30 metal case
• DIN-Rail mount
• Wall mount
• Magnet mount
• Grounding point
Operating Temperature
• - 40° – 75° C (-40° – 167° F)
Operating Humidity
• Max. 95 % non-condensing
Dimensions
• 150 x 145 x 26.7mm (5.9 x 5.7 x 1.1 in.)
Weight
• 580g (1.28 lb.)
Certifications
• CE
• FCC
• UL
• Shock (IEC 60068-2-27)
• Freefall (IEC 60068-2-32)
• Vibration (IEC 60068-2-6)
• IEC 61000-4-2
• IEC 61000-4-4
• IEC 61000-4-5
Warranty
• Lifetime
Package Contents
• TI-PG62F
• Quick Installation Guide
• Removable terminal block
• DIN-Rail, wall and magnet mount kit
TRENDnet offers a lifetime warranty for all of its metal-enclosed network switches that have been purchased in the United States/Canada on or after 1/1/2015. Cooling fan and internal power supply carry a one-year
warranty.
20675 Manhattan Place • Torrance • CA 90501 • USA • T: 1-888-326-6061 • F: 1-310-961-5511 • sales@trendnet.com • www.TRENDnet.com
TRENDnet is a registered trademark. Other Brands and product names are trademarks of their respective holders. Information provided in this document pertain to TRENDnet products and is subject to change at
any time, without notice. For the most recent product information please visit http://www.trendnet.com. Copyright © TRENDnet. All Rights Reserved.
Updated: 5/18/2020
TI-PG62F
All references to speed are for comparison purposes only. Product specifications, size, and shape are subject to change without notice, and actual product appearance may differ from that depicted herein.