User's Guide

11
Step 5. Check the Enabled option to activate the remote
power control support feature of the back panel serial
port of the TK-IP101.
Once the
Enabled
option is checked, a subsequent
Power Device Login option will appear for you to decide
whether to enter the login script. The TK-RP08 does not
require a login script. Hence you don’t have to enter any
script.
Other options:
Simple Users Can Control Power
Check this box if you want that simple users be able to power on and power
off the computers. By default, the TK-IP101 allows only Super admin and
admin the right to power on/off the computer from the viewer Quick Menu.
If you want to allow this feature to simpler users, you can check this option.
Power Device Login
Depending on the Serial Power control device you used behind TK-IP101,
sometimes you will need a login script to login or initialize your power
control device. If that is the case, just check the Power Device Needs a
Login option, and a Login Dialog field will appear for you to enter your
login script. In this case, you don’t have to enter any script, since TK-RP08
does not need any.
After you have made all modifications, click Store Settings
to save your settings and then hit Apply Settings/Restart
Servers to validate these new settings. Every change you
have made on this page will NOT apply until you hit Apply
Settings/Restart Servers!
Configure the Power Control Command
for each and every port on the TK-IP101
Step 6. Go to the KVM Server/Computers page.
The various settings on this page are KVM port-specific
because a computer is first identified by the KVM port it is
attached to. Select the target port on which your subsequent
settings on this page are directed. You can use the drop-
down combo box as well as use the Previous and the Next
button to navigate to a specific port.
Important Note: when using a power control device,
please note that some newer computers will require some
BIOS option adjustment to restart when power is coming
back. Otherwise they will not restart without a push of the
computer power button. Usually, you should enable the
Power Loss Restart
option on your computer BIOS (or
similar option depending on the BIOS vendor), so that your
computer can boot up when the power control device is
feeding power again
.
Step 6-1. Configure the Power down and Power On
command for each and every port on the IP KVM Switch.
First, you select the 1
st
port and configure the Power Down
and Power Off command, (and if necessary the delay time
between the Power Off and Power On Command, or you can
leave it as default) then hit the Store Settings buttons. Then,
you go the 2
nd
port and then do the configurations likewise,
then hit the Store Settings button. …. So you configure
every port right through to the last port of your IP KVM
switch, and then hit the Store Settings button. Then you hit
the Apply Settings button to make the changes effective.
Power down command: /Fbbp\
F: OFF
bb: 2-digit bank number on which the target port resides.
p: 1-digit target port number.
e.g. If you want to turn off port 3 on bank 1. Then you have
to enter:
/F013\
Power on command: /Obbp\
O: ON
bb: 2-digit bank number on which the target port resides.
p: 1-digit target port number.