TRENDnet User’s Guide Contents Product Overview ...........................................................................1 Package Contents .......................................................................................................... 1 Features ......................................................................................................................... 1 Product Hardware Features...........................................................................................
TRENDnet User’s Guide Add, modify, and remove VLANs ....................................................................... 32 Configure VLAN Port Settings ............................................................................ 33 Configure the VLAN forwarding Table ............................................................... 34 View the switch VLAN dynamic forwarding table .............................................. 35 Create a private VLAN .......................................................
TRENDnet User’s Guide TPE-P521ES Features Product Overview 5-Port Gigabit PoE+ Powered EdgeSmart Switch with PoE Pass Through, model TPEP521ES, is powered by a PoE+ switch or injector, no AC adapter is required. It features two gigabit non-PoE ports, and two gigabit PoE ports to power devices such as IP cameras, VoIP handsets, and wireless access points. Reducing unnecessary switch complexity, this EdgeSmart switch is equipped with only the most commonly used managed switch features.
TRENDnet User’s Guide Ports TPE-P521ES Product Hardware Features One gigabit PoE+ input port, two gigabit PoE output ports, and two gigabit ports provides a 10Gbps switching capacity. Front View PoE Power Two gigabit PoE pass through ports with an 18W total PoE power budget. Compact Design With a compact and lightweight housing design this switch is well-suited for desktop installations. Its fanless design is ideal for quiet environments that require silent operation.
TRENDnet User’s Guide LED Indicators LED POWER (Green) Ports 1-5 Right LED (Link/Act) Ports 1-2 Left LED (PoE Status) State ON OFF GREEN AMBER BLINKING OFF GREEN AMBER OFF GREEN Port 5 Left LED (PoE-in Status) AMBER TPE-P521ES Switch Installation Status When the POWER LED is on, the device is powered on. When the device is not receiving power, the PWR LED is OFF. Network speed at 1000 Mbps (Gigabit) Network speed at 10/100 Mbps Data is transmitting/receiving. Ethernet port is not connected.
TRENDnet User’s Guide Basic IP Configuration TPE-P521ES 5. Enter the User Name and Password, and then click Login. By default: User Name: admin Password: admin Note: User name and password are case sensitive. 3. Assign a static IP address to your computer’s network adapter in the subnet of 192.168.10.x (e.g. 192.168.10.25) and a subnet mask of 255.255.255.0. 6. Click System and then click IPv4 Setup. 4.
TRENDnet User’s Guide 7. Configure the switch IP address settings to be within your network subnet, then click Apply. Note: You may need to modify the static IP address settings of your computer’s network adapter to IP address settings within your subnet in order to regain access to the switch. TPE-P521ES NOTE: The configured settings are only applied to the switch’s temporary memory and will be lost upon the next power-cycle.
TRENDnet User’s Guide TPE-P521ES Connect additional devices to your switch You can connect additional computers or other network devices to your switch using Ethernet cables to connect them to one of the available Gigabit Ports (1-4). Check the status of the LED indicators on the front panel of your switch to ensure the physical cable connection from your computer or device. Note: If you encounter issues connecting to your network, there may be a problem with your computer or device network settings.
TRENDnet User’s Guide Accessing switch management interfaces TPE-P521ES System Info View your switch status information Access your switch web management page Note: Your switch default management IP address http://192.168.10.200 is accessed through the use of your Internet web browser (e.g. Internet Explorer®, Firefox®, Chrome™, Safari®, Opera™) and will be referenced frequently in this User’s Guide.
TRENDnet User’s Guide TPE-P521ES System MAC Address, IPv4 Information MAC Address: Displays the switch system MAC address. IP Address – Displays the current IPv4 address assigned to your switch. Subnet Mask – Displays the current IPv4 subnet mask assigned to your switch. Default Gateway – Displays the current gateway address assigned to your switch. Automatic Network Features IPv4 DHCP Client Mode: Displays if your switch IPv4 address setting is set to DHCP client. © Copyright 2018 TRENDnet.
TRENDnet User’s Guide System System Management Set your system information TPE-P521ES NOTE: The configured settings are only applied to the switch’s temporary memory and will be lost upon the next power-cycle. Please follow these next steps to save the configurations to the switch’s NV-RAM to ensure the settings will remain throughout power-cycles and reboots: 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. 2.
TRENDnet User’s Guide IPv4 Settings TPE-P521ES 4. Click Apply. Set your IPv4 settings System > IPv4 Setup This section allows you to change your switch IPv4 address settings. Typically, the IP address settings should be changed to match your existing network subnet in order to access the switch management page on your network. Default Switch IPv4 Address: 192.168.10.200 Default Switch IPv4 Subnet Mask: 255.255.255.
TRENDnet User’s Guide Administration TPE-P521ES 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. 2. Click Continue to return to the Web Configuration of your switch. Change administrator password System > Administration This section explains how to change the administrator password for access to the switch management page. 1. Log into your switch management page (see “Access your switch management page” on page 7). 2.
TRENDnet User’s Guide Timeout TPE-P521ES 2. Click Continue to return to the Web Configuration of your switch. Change web idle login timeout settings System > Timeout This section explains how to modify the switch management page idle timeout settings. 1. Log into your switch management page (see “Access your switch management page” on page 7). 2. Click on System, and click on Timeout. 3. Review the settings. Click Apply to save changes.
TRENDnet User’s Guide TPE-P521ES SNMP Global Settings System > SNMP > Global Settings You can manage a switch by viewing and configuring the management information base (MIB) objects on the device with the Simple Network Management Program (SNMP). This chapter describes how to configure SNMP. A Group Name, IP address of the switch and at least one community string is the minimum required to manage the switch using SNMP.
TRENDnet User’s Guide 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. TPE-P521ES 2. Click on System, click on SNMP, and click on Community Table Settings. 3. Review the settings. Editing SNMP Community Settings 2. Select an Access Right – either Read Write or Read Only. Enter a Community Name (View Policy). If you change the default name on this page, you must also update the Host Settings to match the community name. Note: Host Settings page.
TRENDnet User’s Guide 2. TPE-P521ES Select the SNMP Version, either v1 or v2c, that is configured for the host management device. Enter a Community String (Community Name) that you have defined previously in the SNMP Community table. The Community String must correlate with one of the communities displayed on the SNMP Community Table page. If you enter a Community String that has not been pre-defined, the Trap Host entry is displayed, but agent/manager communication fails. Click Apply.
TRENDnet User’s Guide TPE-P521ES Refresh: Clicking Refresh will refresh the data on the page. Statistics View Statistics System > Statistics Statistics provide important information for troubleshooting switch problems at the port level. The Web Management Utility provides a two statistics charts, including Traffic Information and Error Information. View Traffic Information Statistics System > Statistics > Traffic 1.
TRENDnet User’s Guide TPE-P521ES IEEE 802.3az EEE Enable IEEE 802.3az Power Saving Mode System > IEEE 802.3az EEE The IEEE 802.3 EEE standard defines mechanisms and protocols intended to reduce the energy consumption of network links during periods of low utilization, by transitioning interfaces into a low-power state without interrupting the network connection. The transmitted and received sides should be IEEE802.3az EEE compliance. By default, the switch disabled the IEEE 802.3az EEE function.
TRENDnet User’s Guide TPE-P521ES Network o Enabled - This parameter indicates the port is able to send and receive Ethernet frames. o Disabled - This parameter indicates the port is not able to send and receive Ethernet frames. Physical Interface Configure Physical Interfaces Network > Physical Interface This section allows you to configure the physical port parameters such as speed, duplex, flow control, and jumbo frames.
TRENDnet User’s Guide Flow Ctrl: Flow Control, This parameter reflects the current flow control setting on the port. The switch uses a special pause packet to notify the end node to stop transmitting for a specified period of time. The possible values are: o Enabled - This parameter indicates that the port is permitted to use flow control. o Disabled - This parameter indicates that the port is not permitted to use flow control.
TRENDnet User’s Guide TPE-P521ES Spanning Tree Spanning Tree Global Settings Network > Spanning Tree > Protocol Spanning Tree Protocol (STP) provides network topology for any arrangement of bridges/switches. STP also provides a single path between end stations on a network, eliminating loops. Loops occur when alternate routes exist between hosts. Loops in an extended network can cause bridges to forward traffic indefinitely, resulting in increased traffic and reducing network efficiency. 1.
TRENDnet User’s Guide NOTE: The configured settings are only applied to the switch’s temporary memory and will be lost upon the next power-cycle. Please follow these next steps to save the configurations to the switch’s NV-RAM to ensure the settings will remain throughout power-cycles and reboots: 1. 2. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. TPE-P521ES 3. Review the settings. For each entry, click Apply to save changes.
TRENDnet User’s Guide 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. TPE-P521ES Trunk Configure port trunk settings (Trunk/Link Aggregation) Network > Trunk The trunking function enables the cascading of two or more ports for a combined larger total bandwidth. Only 1 trunk groups may be created, supporting up to 4 ports. Select the ports to be trunked together, and click Apply to activate the selected trunking groups.
TRENDnet User’s Guide LACP List lists the current active trunking groups and their respective ports. Clicking Delete removes the group. TPE-P521ES Mirroring Configure port mirror settings Network > Mirroring Port mirroring allows you to monitor the ingress and egress traffic on a port by having the traffic copied to another port where a computer or device can be set up to capture the data for monitoring and troubleshooting purposes.
TRENDnet User’s Guide To copy both trasmitted and received data, select Ingress/Egress as the Frame Type and check the port number(s) under the section or you could click All to copy data received on all ports. TPE-P521ES Loopback Detection Enable loopback detection Network > Loopback Detection The loopback detection feature allows the switch to detect and prevent disruption from loops that occur on uplink or downlink switches directly connected to your switch. 1.
TRENDnet User’s Guide In the Loopback Detection table, select one of the Loopback Detection Status choices from the pull down menu: Enabled: This selection enables the Loopback Detection feature for each port. This state must be enabled along with the Status field at the top of the page before this feature can be active on the selected port. Disabled: This selection disables the Loopback Detection feature on the selected port. TPE-P521ES 1.
TRENDnet User’s Guide Static Unicast Add static unicast entries to the switch Network > Static Unicast TPE-P521ES In the list, you can click Modify to modify an entry or click Delete or delete the entry. You can also click Delete All to delete all the entries in the list. If the entries span multiple pages, you can navigate page number in the Page field and click Go or you can click First, Previous, Next, and Last Page to navigate the pages.
TRENDnet User’s Guide Static Multicast Add static multicast entries to the switch Network > Static Multicast TPE-P521ES In the list, you can click Modify to modify an entry or click Delete or delete the entry. If the entries span multiple pages, you can navigate page number in the Page field and click Go or you can click First, Previous, Next, and Last Page to navigate the pages. In this section, you can add static multicast entries to the switch configuration. 1.
TRENDnet User’s Guide IGMP Snooping TPE-P521ES 2. Click Continue to return to the Web Configuration of your switch. Configure IGMP Snooping Settings Network > IGMP Snooping > Settings 1. Log into your switch management page (see “Access your switch management page” on page 7). 2. Click on Network, click on IGMP Snooping, and click on Settings. 3. Review the settings. Click Apply to save the settings.
TRENDnet User’s Guide In the list, you can click Delete to delete the entry. If the entries span multiple pages, you can navigate page number in the Page field and click Go or you can click First, Previous, Next, and Last Page to navigate the pages. TPE-P521ES Bandwidth Control Configure Storm Control Network > Bandwidth Control > Storm Control This section allows you to configure the broadcast, multicast, and unknown unicast (also known as DLF or Destination Lookup Failure) storm settings for the switch.
TRENDnet User’s Guide 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. 2. Click Continue to return to the Web Configuration of your switch. TPE-P521ES NOTE: The configured settings are only applied to the switch’s temporary memory and will be lost upon the next power-cycle. Please follow these next steps to save the configurations to the switch’s NV-RAM to ensure the settings will remain throughout power-cycles and reboots: 1.
TRENDnet User’s Guide Set Egress Rate Limiting TPE-P521ES 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. 2. Click Continue to return to the Web Configuration of your switch. Network > Bandwidth Control > Egress Rate Limiting This section allows you to set the egress (transmit) rate for each switch port. 1. Log into your switch management page (see “Access your switch management page” on page 7). 2.
TRENDnet User’s Guide TPE-P521ES VLAN Tagged/Untagged/Not Member VLAN Ports Add, modify, and remove VLANs On a port, the tag information within a frame is examined when it is received to determine if the frame is qualified as a member of a specific tagged VLAN. If it is, it is eligible to be switched to other member ports of the same VLAN. If it is determined that the frame’s tag does not conform to the tagged VLAN, the frame is discarded.
TRENDnet User’s Guide Management VLAN – Select the VLAN ID from any user created VLANs for the management VLAN and additionally displays the VLAN Name. TPE-P521ES 2. Click Continue to return to the Web Configuration of your switch. Note: By default, the default VLAN VID 1 is set as the Management VLAN. In this list, you can click Modify to modify an entry or click Delete or delete the entry.
TRENDnet User’s Guide NOTE: The configured settings are only applied to the switch’s temporary memory and will be lost upon the next power-cycle. Please follow these next steps to save the configurations to the switch’s NV-RAM to ensure the settings will remain throughout power-cycles and reboots: 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. TPE-P521ES Static Multicast Address entries will be cleared. 802.1X authenticated records will be cleared.
TRENDnet User’s Guide 2. Click Continue to return to the Web Configuration of your switch. TPE-P521ES If the entries span multiple pages, you can navigate page number in the Page field and click Go or you can click First, Previous, Next, and Last Page to navigate the pages.
TRENDnet User’s Guide 1. Log into your switch management page (see “Access your switch management page” on page 7). TPE-P521ES 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. 2. Click Continue to return to the Web Configuration of your switch. 2. Click on Network, click on VLAN, and click on Private. 3.
TRENDnet User’s Guide Voice VLAN Configuring Voice VLANs Network > Voice VLAN This chapter contains a description of the Switch’s Voice VLAN feature and the procedures to create, modify, and delete a voice VLAN configuration. The Voice VLAN feature is specifically designed to maintain high quality, uninterrupted voice traffic through the switch. When talking on a voice over IP phone, a user expects to have no interruptions in the conversation and excellent voice quality.
TRENDnet User’s Guide TPE-P521ES If the IP phone(s) that you are installing cannot be configured with a VLAN ID, then the switch ports should be configured as Static tagged ports within the voice VLAN. Note: Link Layer Discovery Protocol for Media Endpoint Devices (LLDP- MED) is not supported on the switch. Each IP phone that is VLAN aware should be manually configured for the VLAN ID that matches your voice VLAN ID.
TRENDnet User’s Guide 2. TPE-P521ES Click Continue to return to the Web Configuration of your switch. Modify OUI Setting To modify or delete an OUI, it must be first be deleted and then re-created. Configure Voice VLAN OUI settings Network > Voice VLAN > OUI 1. Log into your switch management page (see “Access your switch management page” on page 7).
TRENDnet User’s Guide 2. TPE-P521ES Click Continue to return to the Web Configuration of your switch. © Copyright 2018 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide TPE-P521ES QoS (Quality of Service NOTE: The configured settings are only applied to the switch’s temporary memory and will be lost upon the next power-cycle. Please follow these next steps to save the configurations to the switch’s NV-RAM to ensure the settings will remain throughout power-cycles and reboots: When a port on an Ethernet switch becomes oversubscribed, its egress queues contain more packets than the port can handle in a timely manner.
TRENDnet User’s Guide Port Priority Set Port Priority QoS > Port Priority The Port Priority values are assigned to an untagged frame at ingress for internal processing in the switch. This procedure explains how to change the default mappings of port priorities to the User Priority. This is set at the switch level. You cannot set this at the per-port level. To change the port priority mappings, perform the following procedure.
TRENDnet User’s Guide DSCP TPE-P521ES 1. From the menu on the left: click on Save, then click the blue button Save Settings to Flash. 2. Click Continue to return to the Web Configuration of your switch.
TRENDnet User’s Guide Scheduling Algorithm TPE-P521ES 2. Click Continue to return to the Web Configuration of your switch. Set the Scheduling Algorithm QoS > Scheduling Algorithm 1. Log into your switch management page (see “Access your switch management page” on page 7). 2. Click on QoS and click on Scheduling Algorithm. 3. Review the settings. Click Apply to save the settings.
TRENDnet User’s Guide TPE-P521ES Power Budget PoE Power over Ethernet The main advantage of PoE is that it can make installing a network easier. The selection of a location for a network device is often limited by whether there is a power source nearby. This constraint limits equipment placement or requires the added time and cost of having additional electrical sources installed.
TRENDnet User’s Guide Configure PoE settings TPE-P521ES PoE > PoE Configuration Current (mA) - Indicates the Current in milliamps that the port is supplying to the PD. 1. Log into your switch management page (see “Access your switch management page” on page 7). 2. Click on PoE and click on PoE Configuration. 3. Review the settings for each port. Next to each port entry, click Apply to save the settings. Port - Indicates the port with a specific PoE status and that you are configuring.
TRENDnet User’s Guide Tools Firmware Upgrade TRENDnet may periodically release firmware upgrades that may add features or fix problems associated with your TRENDnet switch model and version. To check if there is a firmware upgrade available for your device, please check your TRENDnet model and version using the link. http://www.trendnet.com/downloads/ In addition, it is also important to verify if the latest firmware version is newer than the one your switch is currently running.
TRENDnet User’s Guide 5. Depending on your web browser, click Browse or Choose File and navigate to the folder on your computer where the unzipped firmware file (.bin) is located and select it. Note: While the switch in the upgrade state, you will not be able to access the management interface until you reboot the device.
TRENDnet User’s Guide TPE-P521ES Diagnostics o Open in Cable: There is an open wire within the cable. Cable Diagnostics Test o Short in Cable: Two wires are shorted together within the cable. Tools > Diagnostics o Cross talk in Cable: There is crosstalk detected between one pair of wires and another pair within the cable. The switch provides a basic cable diagnostic tool in the GUI for verifying the pairs in copper cabling and estimated distance for troubleshooting purposes.
TRENDnet User’s Guide TPE-P521ES Reboot To reset your switch to factory defaults: Reboot/Reset to Factory Defaults You may want to reset your switch to factory defaults if you are encountering difficulties with your switch and have attempted all other troubleshooting. Before you reset your switch to defaults, if possible, you should backup your switch configuration first, see “Backup and restore your switch configuration settings” on page 79.
TRENDnet User’s Guide TPE-P521ES Using the Edge Smart Switch Management Utility The Web Smart Management Utility allows you to do the following: You can easily discover all TRENDnet web smart switches on your network using the discover feature. You can modify the IP address settings, change the admin password, and upgrade firmware for multiple switches.
TRENDnet User’s Guide 5. At the Installation, click Install. TPE-P521ES Using the Utility Launching the Utility Upon completing the software installation, a desktop shortcut is automatically created. Double-click the icon to start the utility or open the utility if it is already running. Closing the utility will exit the application. You can also click Exit at the bottom of the utility user interface to exit the application. 6. In the Completion window, click Finish.
TRENDnet User’s Guide TPE-P521ES Discovery List Monitor List This is the list where you can discover all the Web management devices in your network. All the Web Smart switches in the Monitor List can be monitored; you can also receive the trap and show the status of the device. By pressing the “Discovery” button, you can list all the Web Smart Management switches in the discovery list.
TRENDnet User’s Guide Device Setting TPE-P521ES Firmware Upgrade: When the device has a new function, there will be a new firmware to update the device, use this function to update. You can set the device by using the function key in the Device Setting Dialog box. Configuration Setting: In this Configuration Setting, you can set the IP Address, Subnet Mask, Gateway, Group Interval, System name, Location and IP Mode.
TRENDnet User’s Guide TPE-P521ES Main Menu Options In the “File TAB”, there are Monitor Save, Monitor Save As, Monitor Load and Exit. Monitor Save: To record the setting of the Monitor List to the default, when you open the Web Management Utility next time, it will auto load the default recorded setting. Monitor Save As: To record the setting of the Monitor List in appointed filename and file path. Monitor Load: To manually load the setting file of the Monitor List.
TRENDnet User’s Guide Technical Specifications Standards IEEE 802.1d IEEE 802.1w IEEE 802.1p IEEE 802.1Q IEEE 802.3 IEEE 802.3u IEEE 802.3x IEEE 802.3ab IEEE 802.3ad IEEE 802.3af IEEE 802.3at IEEE 802.
TRENDnet User’s Guide Port Mirror One to one Many to one Operating Temperature 0° – 40° C (32° – 104° F) Operating Humidity Storm Control TPE-P521ES Broadcast (Min. Limit: 8Kbps) Multicast (Min. Limit: 8Kbps) Loopback Detection Max. 90% non-condensing Dimensions 150 x 97 x 28.6mm (5.9 x 3.81 x 1.12 in.) Weight Special Features PoE Powered Enable/disable 802.3az Power Saving Wall mountable Power IEEE 802.3at (30W) or IEEE 802.3af (15.
TRENDnet User’s Guide Quick Installation GuideTroubleshooting Q: I typed http://192.168.10.200 in my Internet Browser Address Bar, but an error message says “The page cannot be displayed.” How can I access the switch management page? Answer: 1. Check your hardware settings again. See “Switch Installation” on page 7. 2. Make sure the Power and port Link/Activity and WLAN lights are lit. 3.
TRENDnet User’s Guide Appendix TPE-P521ES Note: If you are experiencing difficulties, please contact your computer or operating system manufacturer for assistance.
TRENDnet User’s Guide In MAC OS 10.4, from the Show drop-down list, select Built-in Ethernet and select the TCP/IP tab. In MAC OS 10.5/10.6, in the left column, select Ethernet. e. Configure TCP/IP to use a static IP. In MAC 10.4, from the Configure IPv4, drop-down list, select Manually and assign your network adapter a static IP address. Then click the Apply Now button. In MAC 10.5/10.6, from the Configure drop-down list, select Manually and assign your network adapter a static IP address .
TRENDnet User’s Guide TPE-P521ES Federal Communication Commission Interference Statement RoHS This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
TRENDnet User’s Guide Česky [Czech] TRENDnet tímto prohlašuje, že tento TPE-P521ES je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 2014/30/EU a 2004/108/ES. Dansk [Danish] Undertegnede TRENDnet erklærer herved, at følgende udstyr TPEP521ES overholder de væsentlige krav og øvrige relevante krav i direktiv 2014/30/EU og 2004/108/EF.
TRENDnet User’s Guide Limited Warranty TRENDnet warrants only to the original purchaser of this product from a TRENDnet Limited Warranty In the event that, after evaluation, TRENDnet cannot replace the defective product or there is no comparable model available, we will refund the depreciated value of the product. authorized reseller or distributor that this product will be free from defects in material and workmanship under normal use and service.
TRENDnet User’s Guide Limited Warranty shipping from outside of the USA and Canada are responsible for any return shipping CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, and/or customs charges, including but not limited to, duty, tax, and other fees.