Quick Installation Guide TK-802R
Table of Contents English 1. Before You Start 2. How to Install 3. Operation 1 1 2 5 Troubleshooting 9 Version 08.31.
1. Before You Start ENGLISH Package Contents ? TK-802R ? Multi-Language Quick Installation Guide ? Daisy-Chain Cable ? Rack mount kit FRANÇAIS ? AC Power Adapter (9V DC, 1A) System Requirements DEUTSCH ? PS/2 Keyboard ? PS/2 Mouse ? VGA Compatible Monitor ? PS/2 KVM cables (e.g.
DEUTSCH 2. Connect the shared PS/2 keyboard, monitor, and PS/2 mouse to the KVM switch's Console Port. FRANÇAIS 1. Turn OFF all computers and their peripherals, and then disconnect all power cords. ENGLISH 2. How to Install 5. Turn ON the connected computers one-by-one and wait until each computer's desktop appears. 2 ÐÓÑÑÊÈÉ 4. Use the KVM cables to connect each computer to the KVM switch. Note: Do not use the supplied daisy-chain cable to connect to your computer.
ÐÓÑÑÊÈÉ ESPAÑOL DEUTSCH FRANÇAIS ENGLISH Daisy-Chain Note: 1. Must use the daisy chain cable provided with the KVM switch 2. Only daisy chain the KVM switch with another TK-802R 3. Stackable up to 16 KVM switches 6. Connect one end of the daisy-chain to the Daisy chain in port on the first (master) KVM switch. 7. Connect the opposite end of the daisy-chain cable to the Console port on the second switch (slave1) 8.
Note: If you would like to mount the KVM switch to a EIA 19” equipment rack, install the included mounting brackets to the sides of the KVM switch, secure them with the screws provided, and then mount the KVM switch to the equipment rack with the hardware provided by the equipment rack manufacturer. 11. Attach the mounting brackets to both sides of the switch and secure them with the provided screws. 12. Carefully position the switch onto the rack.
FRANÇAIS ENGLISH 3. Operation Note: To switch between computers, you can use the front-panel push buttons or the Hot Key commands. LED Indicators Bank Number: Indicates the number or sequence of the switch when daisy chained. This number is 01 when the switch is not daisy chained. Red LED light: KVM cable is connected and PC is powering the KVM switch. ÐÓÑÑÊÈÉ ESPAÑOL DEUTSCH Green LED light: Indicates the selected PC port is active, whether the computer is turned on or off.
Hot Key command = Scroll Lock + Scroll Lock + Command key(s) To select a specific PC port Select PC = Scroll Lock + Scroll Lock + A + B + Y + Z Bank number Port number Scroll Lock + Scroll Lock + 0 + 1 + 0 + 1 Select PC = Scroll Lock + Scroll Lock + 1 + 0 + 0 + 8 For a list of all the Hot Key commands, please see the Quick Reference Sheet. 6 ÉÈÊÑÑÓÐ Note: When using the KVM switch standalone, type in 0 + 1 for the bank number.
ENGLISH On Screen Display (OSD) Control To activate the OSD Menu, use the following hot-key command: ÐÓÑÑÊÈÉ ESPAÑOL DEUTSCH FRANÇAIS Scroll Lock + Scroll Lock + Space Bar Note: For detailed information about the operation of the OSD, please refer the Quick Referece Sheet.
Quick Reference Sheet for TK-802R Hot Keys Scroll Lock + Scroll Lock + A + B + Y + Z Select PC (ab) = bank number (yz)= 2-digit channel number Front-panel Description Use arrow keys to select and then hit enter Press Push Button for a specific port to the switch Select the active bank (switch) and channel (computer) Page Down --- Select the next lower bank when multiple switches are daisy-chained Page Up --- Select the next higher bank when multiple switches are daisy chained --- --- Toggle
Troubleshooting Do I need to use the included external AC adapter? It is recommended that you use the included external AC adapter with the TK-802R KVM switch. Can I connect or disconnect the KVM cables while the computers are turned on? Yes, you can connect or disconnect the KVM cables while the computers are turned on, because the interface is Hot-Pluggable.
Limited Warranty TRENDnet warrants its products against defects in material and workmanship, under normal use and service, for the following lengths of time from the date of purchase.
WARRANTIES EXCLUSIVE: IF THE TRENDNET PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, THE CUSTOMER'S SOLE REMEDY SHALL BE, AT TRENDNET'S OPTION, REPAIR OR REPLACE. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Certifications This equipment has been tested and found to comply with FCC and CE Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received. Including interference that may cause undesired operation. Waste electrical and electronic products must not be disposed of with household waste. Please recycle where facilities exist. Check with you Local Authority or Retailer for recycling advice.
Product Warranty Registration Please take a moment to register your product online. Go to TRENDnet’s website at http://www.trendnet.com/register Copyright ©2009. All Rights Reserved. TRENDnet.