Web Cruiser User's Guide TW200 TW400 P/N 9560660037
Sensitive Information This page contains a security password. If the device password is lost or forgotten, this meta-password will allow access to the device configuration. This meta password will function only in Terminal Configuration mode. [+-*/] Please remove this page and treat it with the same discretion you would treat your regular password. Carelessness in password policy may lead to serious compromises in system security.
FCC Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that my cause undesired operation. CE Marking Warning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Copyright 1998. All Rights Reserved.
TABLE OF CONTENTS 1 INTRODUCTION ...............................................................1 Web Cruiser Features ....................................................1 Package Contents............................................................4 Meta Password................................................................4 Description ......................................................................4 TW200 .......................................................................5 TW400 .............
Port Configuration................................................... 29 Advanced Setup ...................................................... 34 Status Screen ........................................................... 35 E-Mail Configuration .............................................. 38 5 OPERATION .................................................................... 41 IP Address Configuration ........................................... 41 PC Address Configuration......................................
1 Introduction C ongratulations on the purchase of your new Error! Reference source not found. Internet Access device The Error! Reference source not found. will allow multiple SOHO (Small Office Home Office) users to share Internet user accounts. It provides a low-cost method of giving users of your network access to the vast resources available on the Internet. Once the Error! Reference source not found. is installed and configured, the Internet is just a click away.
Error! Reference source not found. User Guide can seamlessly connect to the Internet as if you had a permanent connection. This sophisticated, yet easy-to-use device incorporates the following features. • Dial-On-Demand. A connection is established to the Internet as required. • User-Configurable Bandwidth Utilization. When using multiple modems or ISDN TAs, users can choose between “Time Saving Mode” (use all bandwidth) or “Money Saving Mode” (maximize bandwidth utilization). • Inactivity Time Out.
Introduction • Remote Management. The Error! Reference source not found. can be managed from a workstation anywhere on the LAN, using a WEB browser. • E-Mail Gateway. The Error! Reference source not found. can act as a Gateway for incoming E-Mail, allowing LAN users to share E-Mail accounts. Up to 4 accounts and 50 users are supported. • Firewall Protection.
Error! Reference source not found. User Guide Package Contents The following items should be included: • The Error! Reference source not found. • Power Adapter • Serial Cable (for configuration ONLY) • This User’s Manual If any of the above items are damaged or missing, please contact your dealer as soon as possible. Meta Password Please remove the Sensitive Information page at the front of this manual and store it in safe place.
Introduction Error! Reference source not found. Figure 2: Error! Reference source not found. LED Indicators 1 Error LED This LED is used to indicate an error, but it will normally light up during power On. See the following LED Status Table for more details. 2 Link LED This LED should be on during normal operation. For more information, see the following LED Status Table . 3, 4 Serial Port Indicators These LEDs flash when the relevant port is in use.
Error! Reference source not found. User Guide Error! Reference source not found. Figure 3: Error! Reference source not found. LED Indicators 1 Error LED This LED is used to indicate an error, but it will normally light up during power On. For more information, see the following LED Status Table. 2 Link LED This LED should be on during normal operation. For more information, see the following LED Status Table. 3, 4 5, 6 Serial Port Indicators These LEDs flash when the relevant port is in use.
Introduction Back Panel The following diagram shows the back panel of the Error! Reference source not found.. The Error! Reference source not found. is identical except for having 2 serial ports rather than 4. Figure 4: Back Panel (Error! Reference source not found.) 1 Power port Connect the power adapter here. 2 10Base2 port Connect 10Base2 cabling here. 3 10BaseT LED indicator. This will light when the 10BaseT connector is in use. 4 10BaseT port Connect 10BaseT cabling here.
Error! Reference source not found. User Guide LED Status Table (All Models) Link Error Description On On During power On, both LEDs should light then the Red LED should go off. If both LEDs stay on, there is a hardware problem. On Off Normal Operation (Power On Self Test OK) Flashing Off Normal Operation (Receiving Packets from LAN) Steady flashing of both LEDs Terminal configuration mode. (Both DIP switches ON.
2 Installation Requirements • Ethernet Network employing 10BaseT or 10Base2 cable and the TCP/IP protocol. • An external modem or ISDN TA (Terminal Adapter). • Configuration serial cable for Terminal mode configuration (supplied). • Single user account with a local ISP. Procedure The installation choices are as follows. Configure, then Install Configuration is done using a serial cable connection and a VT100 terminal compatible program, before installation.
Error! Reference source not found. User Guide Error! Reference source not found. is allocated a new IP Address during configuration. LAN Installation Installing your new Error! Reference source not found. in your existing Ethernet LAN is quick and easy. Simply follow the instructions below: 1. Choose an Installation Site Select a place on the network to install the Error! Reference source not found.. Remember that you need phone jacks and power outlets near your chosen location. 2.
Installation 10BaseT Cabling: If your network uses 10BaseT cable, insert one end into the Error! Reference source not found.’s RJ-45 jack and the other end into the 10BaseT hub. Keep in mind that the maximum effective length from the hub to the device is 100 meters. Warning: Do not attempt to connect more than one type of cable at the same time or change the network cable while the Error! Reference source not found. is powered On. 3.
Error! Reference source not found. User Guide ware problem. For more information on the LEDs, refer to the LED Status table in Chapter 1.
Installation This page was deliberately left blank.
3 Configuration Settings Regardless of the configuration method used, you will be required to enter the following information. Port Configuration Internet Connection User Name Enter the account name provided by your ISP. This name will be used to log in to the ISP’s server. Password Enter the current password for the above account. Verify Password Re-enter the password to ensure it is correct. Telephone Up to 3 telephone numbers can be entered; only 1 is required.
Configuration IP Address Enter the IP address assigned to you by your ISP. If the ISP issues dynamic IP addresses, leave this field as 0.0.0.0. (With dynamic IP addresses, a valid address is provided upon connection.) DNS IP Address The DNS (Domain Name Server) translates names (e.g. microsoft.com) to IP Addresses. Enter the DNS IP address supplied or recommended by your ISP. Modem/ISDN Configuration Model Initial String • If your model is listed, simply select it and you are finished.
Error! Reference source not found. User Guide Advanced Port Settings Most users should not have to change these settings. Port Settings Enable/Disable If Enabled, a connection will be made as needed. Use "Disable" to temporarily disable the port when required. Hang up after Idle Time If a connection remains inactive, it is terminated after this time period. Allowable range is 0-99 minutes. For a leased line, set this value to 0.
Configuration Auto Answer Off Command Enter the command string which instructs your modem or ISDN TA not to answer incoming calls. Script File If your ISP uses a standard PPP connection and authentication, you do NOT need a script file. Script files are used to automate the log-in process when connecting with ISPs that use non-standard log-ins or proprietary security measures. For example, if you connect to the Internet via CompuServe, you DO need a script file.
Error! Reference source not found. User Guide Advanced Setup LAN Settings Device IP Address IP address for the Error! Reference source not found.. Use the default value unless the address is already in use. Router IP Address If you have a router, enter its IP Address. Otherwise, leave this at the default value. Network Mask The default value 255.255.255.0 is OK for small networks. For larger networks, ask the LAN administrator.
Configuration DHCP Server A DHCP server provides a valid IP address (and the Gateway and DNS addresses) to a DHCP client (PC or device) upon request. The Error! Reference source not found. can act as a DHCP server. Enable/Disable If Enabled, the Error! Reference source not found. will function as a DHCP server. The default value is Disabled. Start IP Address Finish IP Address The I.P. Start Address and I.P. Finish Address fields set the values used by the DHCP server.
Error! Reference source not found. User Guide is provided in Win 95’s TCP/IP stack. See IP Address Configuration on page 41 for details.
Configuration E-Mail Accounts The Error! Reference source not found. allows many users to share the E-Mail Account(s) provided by your ISP. Up to 4 E-Mail accounts and 50 users are supported. The E-mail address is formed by combining the User id and the Account name, as shown by the following example (Note: The "" and < > form part of the address, and must be included): "user_id" To use this feature: • The following data must be entered.
Error! Reference source not found. User Guide User Information User ID In your Browser, existing users are shown in a drop-down list. You can select a user from this list to change their details. When adding a new user, the dropdown list is ignored; just enter the details for the new user. Note: • Multiple words are NOT allowed in user IDs. • Punctuation and special characters should NOT be used in User IDs. • User IDs are case insensitive. Password The password for the current user.
4 Configuration Programs There are 2 methods of configuration: • Terminal Mode, using the supplied serial cable and a communications program. • Browser mode, which requires the use of your existing WEB browser. This uses the LAN connection, so the device must be installed on the LAN first. Terminal Mode Configuration Procedure 1. With the power Off, use the supplied serial cable to connect your PC to the serial port on the Error! Reference source not found.. For multi-port models, you MUST use Port 1. 2.
Error! Reference source not found. User Guide Setting Value Terminal Emulation VT100 mode Baud Rate 19200bps Data Bits 8-bit Parity no parity Stop Bits 1 stop bit Flow Control Xon/Xoff OR None 4. Start the configuration program by connecting the power to the Error! Reference source not found.. If nothing appears on your screen, press ESC. 5. Configure the Error! Reference source not found. as described in the following section. Save the configuration data before exiting. 6.
Configuration Programs Navigation & Data Input Once the Error! Reference source not found. is powered On, the configuration program will automatically start. If nothing appears on your screen, press ESC. Use the TAB or cursor keys to move to the desired field and press ENTER. You can then input a value directly, or select from a predefined list of values. Note that those options contained in brackets [ ] have submenus. The following table lists all available keystrokes.
Error! Reference source not found. User Guide Terminal Configuration Screens Once the device is powered on, the configuration program will start. If nothing appears on your screen, press the ESC key. The first screen will have a menu selection for each port. The 4-port model looks as follows: [ Basic configuration ] Local LAN: >Device IP address: 192.168.0.1 Network mask: 255.255.255.0 Version 5.
Configuration Programs Phone number: 117 Serial line speed: 19200 bps Hang up after idle time more than 15 minutes Port enable: Yes [Modem AT Commands] [Script File] Refer to Port Configuration on page 13 and Advanced Port Settings on page 15 for details of the port settings, including the Modem AT Commands and Script File. Advanced Settings Selecting the Advanced Settings option will cause the following screen to appear. [ Advanced settings ] >DHCP Server enable: No I.P. Start Address: 192.168.0.
Error! Reference source not found. User Guide E-Mail Configuration Selecting E-Mail Gateway from the Advanced screen will reveal the following screen. [ E-mail Account ] >[Account [Account [Account [Account 1] 2] 3] 4] [User Information] Selecting Account 1 will reveal the following [ E-mail gateway ] >Account 1 Enable: Yes POP3 Mail Server Address: POP3 Mail Server Account name: Password: See Account Information on page 19 for details of these settings.
Configuration Programs [ E-mail gateway User Information ] User name Password Mail account Unrouted Mail 1)> 1 No 2) 1 No 3) 1 No 4) 1 No 5) 1 No 6) 1 No 7) 1 No 8) 1 No 9) 1 No 10) 1 No 11) 1 No 12) 1 No 13) 1 No 14) 1 No 15) 1 No 16) 1 No 17) 1 No 18) 1 No ----------------------------------------------------- See User Information on page 20 for information on these fields. To enter data: • TAB to the desired field • press ENTER • type the data • press ENTER. Repeat for the next field.
Error! Reference source not found. User Guide Browser Mode Configuration Overview This method uses your existing WEB browser. Most WEB browsers should work, provided they support tables and forms. The Error! Reference source not found. must be installed on your LAN first. Connection To establish a connection from your PC to the device: • Start your WEB browser • In the Address box, enter "HTTP://" and the IP Address of the Error! Reference source not found., as in the following example: HTTP://192.168.
Configuration Programs Port Configuration Selecting the Ports hyperlink will display a screen like the following. Figure 5: Select Port Select the port and the required operation, and click OK to move to the Port Configuration screen.
Error! Reference source not found. User Guide Figure 6: Port Configuration Refer to page 13 for details of these settings. Advanced Port Settings Clicking the Advanced Port Settings hyperlink at the top of the screen will take you to the following screen.
Configuration Programs Figure 7: Advanced Port Settings Refer to page 15 for details of these settings. Port Status Screen The Port Status screen is reached by selecting Status/Test on the Select Port screen shown in Figure 5. An example Port Status & Test screen is shown below.
Error! Reference source not found. User Guide Figure 8: Port Status &Test Current Port Displays the current port. On singleport models, this is always "1". Physical Link If operating, the link will show ON. This means the modem was able to connect to the number dialed. PPP Link If ON, a PPP connection was successfully negotiated. Serial Line Speed The connection speed between this device and the modem.
Configuration Programs PPP IP Address The IP Address at the other end of the PPP connection, if one has been established. Modem Log This shows the commands sent to the modem, and any status messages returned by the modem. Note that this is not "live"; you must select Refresh and then click OK to update the information. Operations • Hang Up will hang up the modem, breaking an existing connection. • Dial will establish a connection to the ISP, if no connection currently exists.
Error! Reference source not found. User Guide Advanced Setup Selecting the Advanced hyperlink from the navigation bar will reveal a screen like the following. Figure 9: Advanced Settings See page 17 for details of these settings.
Configuration Programs Status Screen The Status screen can be reached with the hyperlink on the navigation bar. The following example is for the 4-port model. Figure 10: Status Screen No. of Ports The number of serial ports on this device. Firmware Version Version of the firmware (embedded software, including this program) which is currently installed.
Error! Reference source not found. User Guide cal support staff may ask for this information. Physical Address The hardware address of this device. Hardware ID The hardware ID of this device, used by the manufacturer for identification. IP Address The IP Address of this device. Network Mask The Network Mask value stored in this device. This must match the Network Mask for the LAN segment to which this device is connected. Router IP Address The IP Address (for this LAN segment) of the router.
Configuration Programs Port For each port, the possible status values are "Enabled" or "Disabled". Ports are initially Disabled, but are automatically Enabled when data is entered. This setting is on the Advanced Port Settings screen. DHCP Table This table will be empty unless DHCP has been "Enabled". If DHCP is being used, this table lists the devices which have been allocated IP Addresses by the DHCP server function. Only IP Addresses in use will be listed. • I.P. Address.
Error! Reference source not found. User Guide E-Mail Configuration This screen, reached by selecting the E-Mail hyperlink on the navigation bar, is only needed if you wish to share E-Mail Accounts. It allows to choose an operation for an E-Mail Account or the User List (Shared users).
Configuration Programs E-Mail Accounts This screen is reached by selecting Configure Account from the E-Mail Configuration screen above. Figure 12: E-Mail Accounts See page 19 for details of these settings.
Error! Reference source not found. User Guide E-Mail Users This screen is reached by selecting Configure Users Add/Modify from the E-Mail Configuration screen. See page 20 for more details on these fields. Figure 13: E-Mail Users • To Delete an Existing User: Select the user from the drop-down box, check the Delete above user radio button, and click OK.
5 Operation IP Address Configuration Once the Error! Reference source not found. has been configured and installed in your network, it is ready for use. However, the PCs on your network must be configured correctly. If you have a router, it also needs to be configured correctly. PC Address Configuration The following TCP/IP settings should be checked.
Error! Reference source not found. User Guide dure is described in the following section. For operating systems other than Win 95, check your system documentation. 1. Select the Control Panel - Network option on the Start Menu. You should see a screen like the one following. Figure 14: Network Configuration 2. Select the TCP/IP protocol for your network card. Then click on the Properties button. You should then see a screen like the following.
Operation Figure 15: IP Address (Win 95) 3. Click on the radio button to obtain an IP address automatically, as shown above. Default Gateway Address This should be left blank. The DHCP server will provide this information. DNS (Domain Name Server) This should be “Enabled” but the fields can be left blank. The DHCP server will provide this information also. If DHCP is Disabled IP Address Each workstation must have a unique IP address. There should be no need to change any existing addresses.
Error! Reference source not found. User Guide NO Router Set the Default Gateway Address to the IP address (Device IP Address) assigned to the Error! Reference source not found. during configuration. Router Leave this at the current setting (the address of the router). DNS (Domain Name Server) Enter the DNS address provided or recommended by your ISP. This is the same value that was entered into the DNS IP Address field in the Error! Reference source not found. during configuration.
Operation Internet Access No action is required to gain Internet access. Simply use your Browser as if you had a permanent connection. If no connection currently exists, there will be a short delay while the modem connects to your ISP.
Error! Reference source not found. User Guide E-Mail Configuration IF you are using the Error! Reference source not found. to share E-Mail accounts, then each user sharing an account must configure their E-Mail program with the following data. Name The User ID entered in the E-Mail User Screen of the Error! Reference source not found.. Note the following limitations on User Ids: • Multiple words are NOT allowed • Punctuation and special characters should NOT be used. • User Ids are case insensitive.
Operation • Note that outgoing E-mail is sent normally; only incoming E-mail is processed by the Error! Reference source not found.. • If you find that some of your incoming E-mail does not include your name, and is therefore considered "Unrouted Mail", ask those senders to record your E-Mail Address in the following format. "user_id" • Your printed E-Mail Address (e.g. on your business card) should also show your E-Mail address in the format above.
Error! Reference source not found. User Guide To share this E Mail Account, the entries on the following page would have to be made. Your E-Mail Address would become: "bjones"
Operation Error! Reference source not found. "Mail Account" Account No. 1 Enable Sharing ON (Yes) POP3 Mail Server Address ms02.com POP3 Mail Server Account Name greatco Password 9087654 Error! Reference source not found. "Mail User" User ID bjones Password Secret064 Mail Account 1 Set as Recipient for Unrouted Mail ON (Yes) E-Mail Program Name bjones E-Mail Address greatco@ms02.com SMTP Server (Outgoing Mail) smpt09.com POP3 Server (Incoming Mail) 192.168.0.
A Troubleshooting This chapter covers some common problems that may be encountered while using the Error! Reference source not found. and some possible solutions to them. If you follow the suggested steps and the Error! Reference source not found. still does not function properly, contact your dealer for further advice. Problem 1: I configured and installed the Error! Reference source not found. in the network, but I can’t get it to respond.
A - Troubleshooting found.. Use the “Run” command to enter the following command: Ping xxx.xxx.xxx.xxx where xxx.xxx.xxx.xxx is the IP address assigned to the Error! Reference source not found.’s LAN interface. 3. If the ping command fails, check that the Error! Reference source not found. is connected and ON. If it is connected and on, there is a problem with your LAN. 4. Check that the Port is "Enabled" (Advanced Port Settings). If it is not, you need to use the HTML program to establish a connection.
Error! Reference source not found. User Guide configured to RTS/CTS flow control. Problem 5: Some applications do not run properly when using the Error! Reference source not found.. Solution 5: The Error! Reference source not found. processes the data passing through it, so it is not transparent. Some programs may have limited functionality when used with the Error! Reference source not found.. The number of supported applications is being expanded as rapidly as possible.
A - Troubleshooting This page was deliberately left blank.
B Log Messages This section lists the most common messages which may appear in the Log window of the HTML application. More information on error messages is contained after the table. Message Description Dial on demand Dialing the ISP (“Dial on demand” setting is ON). Try to establish physical connection. The device is trying to connect with the ISP, using the modem. Busy error The number dialed was busy. Physical line is connected Physical connection to ISP has been established.
B - Log Messages Start PPP Having established a physical connection, a PPP connection is now being established. PPP up fail The PPP connection could not be established. PPP up successfully The PPP connection was established successfully. Stop PPP The PPP connection was terminated. This will occur at the end of a session, or an error condition. Try to hang up Attempting to get the modem to hang up. Hang up line manually You have hang up the modem by pressing the “Hang Up” button.
Error! Reference source not found. User Guide Normal Operation The following sequence of messages is typical of normal operation. send “ATDT 0123456789” CONNECT 115200 max phone line speed 28800 bps physical line is connected start PPP ppp up successfully Error Conditions The following messages indicate an error condition. No dial tone The modem could not obtain a dial tone. Check your connections on the phone line and the modem. Busy error The number dialed was busy. Check that the number is correct.
B - Log Messages Time out No response. Check that the modem is ON and properly connected to the Error! Reference source not found.. No carrier, no answer There was no response from the phone number dialed. Check that the phone number is correct, and the modem is working. If both of these are OK, check with your ISP.
C AT Commands Required Settings For the Error! Reference source not found. to function correctly, the modem must be set as follows. Setting Fixed baud rate setting AT Command AT&B1 RTS/CTS flow control AT&K3 DCD to track the presence of a carrier AT&C1 DTR off to hang-up modem AT&D2 DSR always on AT&S0 Modem to return modem-to-modem data link speed ATX4 (see Note below) Note: Modem-to-modem data link speed.
C - AT Command Set For a modem which uses the standard AT commands shown above, the Initial String would look like the following: AT&F&B1&K3&C1&D2&S0X4 The first command (AT&F) sets the modem to the factory defaults, to ensure a consistent starting point. This command string (AT&F) is also the default value. It will work if the modem’s factory defaults match the required settings.
Error! Reference source not found. User Guide Finding the current Initial String If your modem is already working correctly, but you don’t know what the modem initialization string is, you can use the following procedure to find out. 1. Select My Computer, then Dial-Up Networking. 2. Select the icon for your connection, then Properties. 3. Click the Configure button, then the Connection tab, as shown below.
C - AT Command Set 4. Select Advanced to see the screen below. Figure 17:- Advanced Connection (W95) 5. Check the option Record a log file. Then click OK and exit. 6. Use Dial-up Networking to make your on-line connection normally. A log file MODEMLOG.TXT will be created in your Windows directory. 7. Use Notepad or another editor to read and print the file MODEMLOG.TXT. 8. Examine the file to determine the Initial String and also if any Script commands are being used.
Error! Reference source not found. User Guide AT Commands Most modems use the standard AT commands, as shown in the following tables. Consult the manual for your modem to set what AT commands it supports. Basic AT Command Set Command Description Terminate current connection attempt +++ Escape sequence code, entered in data state, wait for modem to return to command state ATA Force answer mode on-line Handshake operation ATBn B0 Select ITU-T V.
C - AT Command Set @ Wait for 5-second silence before proceeding, otherwise return O ANSWER” R Reverse Dial (Originate a call in answer mode) ATDL Dial last number ATDSn Dial number stored in NVRAM at position n.
Error! Reference source not found. User Guide M1 Speaker on until carrier is detected M2 Speaker always on M3 Speaker on after last digit dialed, off at carrier detect ATNn Ring volume control, n=0 disables ring function. n=0-7 ATO Return to on-line state ATP Pulse dial ATQn Result code displayed Q0 Modem returns result code Q1 Modem does not return result code Q2 Return result code but quiet in answer mode (will not show in AT&Vn) ATS0=n Number of rings required before modem answers.
C - AT Command Set V1 Display result codes in verbose form ATXn Result code options. n=0-7 ATZn Reset the modem and set power-on profile.
Error! Reference source not found.
C - AT Command Set This page was deliberately left blank.
D Script files This section describes the script file commands and syntax to be used when creating script files. Script files are only required if your ISP does not use a standard PPP connection and authentication. Commands Three commands can be used to automate a proprietary negotiation process. The commands are as follows: Send Send [msec] Send a data string, with a. [msec] (milliseconds) delay between the sending of each character.
D - Script Files Variables Eleven special string variables can be used in conjunction with the command strings discussed above.
Error! Reference source not found. User Guide Example Script File The following is a sample script file with the proper syntax conventions. This script file could be used to log on to Compuserve. wait 3000 send 100 “\r” wait 3000 send 100 “CIS\r” wait 3000 “:” send 100 “user id\r” wait 3000 send 100 “password\r” wait 60000 “!” send 100 “GO PPPCONNECT\r” Command Explanation wait 3000 Pause for 3 seconds send 100 “\r” Send the carriage return character, pausing for 100 ms between characters.
D - Script Files send 100 “user id\r” Send the string user id, where user id is your log-in name, followed by a carriage return. Pause for 100 ms between each character. wait 3000 Pause for 3 seconds send 100 “password\r” Send the string password, where password is your password, followed by a carriage return. Pause for 100 ms between each character. wait 60000 “!” Wait for 60 seconds to receive the character “!”. If not received in this time, the connection will be dropped.
E Terminal Programs This section explains how to configure and use a Terminal (Communications) program, as required to perform the Terminal Mode Configuration described on page 21. Windows 95 The terminal communications program provided with Windows 95 is called HyperTerminal. To configure it for use with the Error! Reference source not found., the procedure is as follows. 1. Click and follow the selection Start Menu-Programs-Accessories-HyperTerminal. 2. Start the HyperTerminal Program. 3.
E - Terminal Programs Figure 18: HyperTerminal 5. Set “Connect using” to “Direct to Com 1” for serial port 1, as shown in the screen above. (If you are using serial port 2, set “Connect using” to “Direct to Com 2”). 6. Click on the “OK” button. 7. You should now see a screen like the following.
Error! Reference source not found. User Guide Figure 19: HyperTerminal Configuration 8. Change the settings to match the following table.
E - Terminal Programs 9. Click on “OK” when finished. 10. From the “File” menu, select “Properties”. Select the “Settings” tab, and you should see a screen like the following. Figure 20: Null Modem Settings 11. Ensure that the “Emulation” is set to “VT100”. 12. There should be no need to use the “Terminal Setup” button - the default settings should be fine. 13. Click “OK” to close the properties box. 14. You can now connect and power up the Error! Reference source not found..
Error! Reference source not found. User Guide 16. In future, you can start HyperTerminal by clicking on the “Null Modem” icon you created during this session. Windows 3.1 The communications program provided with Windows 3.1 is called “Terminal”. To use it to configure the Error! Reference source not found., the procedure is as follows. 1. Start the “Terminal” Program. By default, it is in the “Accessories” group. 2. Select the “Settings” menu. All of the necessary settings are on this menu. 3.
E - Terminal Programs Figure 21: Win 3.1 Communications 6. Ensure that the settings match those shown in the table below. Setting Value Baud Rate (bits per second) 19200 bps Data Bits 8-bits Parity no parity Stop Bits 1 stop bit Flow Control Xon/Xoff 7. Check that the correct communications port is highlighted (COM 1 = Serial Port 1, COM 2 = Serial Port 2). 8. Exit the “Settings” menu.
Error! Reference source not found. User Guide 9. You can now connect and power up the Error! Reference source not found.. If nothing appears on the screen, press ESC. 10. You can now configure the Error! Reference source not found., as described in Terminal Mode Configuration on page 21.
F Specifications Error! Reference source not found. Model No.: Error! Reference source not found. Dimensions 255mm(W) * 140mm(D) * 40mm(H) Operating Temperature 0° C to 40° C Storage Temperature -10° C to 70° C Protocol: TCP/IP Network Interface: Ethernet 10Base2(BNC) 10BaseT (UTP) Serial Ports: 2 male DB-9 connector Max. Asyn. Speed 230.
Error! Reference source not found. User Guide Error! Reference source not found. Model No.: Error! Reference source not found. Dimensions 255mm(W) * 140mm(D) * 40mm(H) Operating Temperature 0° C to 40° C Storage Temperature -10° C to 70° C Protocol: TCP/IP Network Interface: Ethernet 10Base2(BNC) 10BaseT (UTP) Serial Ports: Error! Reference source not found. - 4 male DB-9 connector Max. Asyn. Speed 230.