The FOD Finder XF radar requires an initial calibration to operate at optimum
performance. The calibration procedure measures the relative response, in phase
and amplitude, of all transmit and receive channel combinations in use by the radar.
This calibration data is collected by acquiring radar data from a single, strong return
source placed in the radar far-field, such as a corner cube, and is measured at twelve
different frequencies across the radar band. The calibration data is then stored on
the internal radar processor and applied to all radar signals during operation to
produce a high-gain beam shape. Importantly, this calibration is applied at the data
processing level and does not require any adjustment of the radar system hardware.
Data for a new calibration can be generated by observing radar returns from a
known target and a new calibration can be applied simply by re-writing the
calibration file on the radar.
The FOD Finder radar is fully calibrated at the factory and then an additional
calibration is performed on site at the time of installation. Calibration is verified by
measuring the return signal from a radar target with a known radar cross-section.
The system continues to automatically update its phase calibration during its
operation based on the data returns from fixed objects within the radar field-of-
view, comparing the returns from those objects at the time of installation to the
returns from those objects at the present time. No input is required by the operator
for the calibration update to occur.