Installation Guide
14
LIGHTING
NOTE: Construction methods are always improving. Please refer to www.trex.com for the most up-to-date installation requirements.
General Information
» Refer to www.trex.com for instructional videos on 
how to install Trex Decklighting.
»  USE TREX TRANSFORMER ONLY. Use of any other 
transformer voids warranty. 
Planning
 NOTE: When designing your deck, plan locations of 
lights, power supply, timer, and dimmer. These should be 
accessible for service. Installing a GFCI outlet is REQUIRED 
to help prevent damage to lighting from electrical surges.
1.   The dimmer remote will work in a 
30' (9 m) radius of the unit.
2.   Dimmer should be installed in a 
dry location. 
3. Timer must be installed 
vertically with receptacle 
facing downwards. Timer must 
be at least 1' (.305 m) from 
ground level when installed as 
per federal safety code height 
regulations. Timer must be in view of the sun to use 
the dusk/dawn feature.
Installing Wiring
NOTE: It is recommended to install wiring and splitters 
before decking and railing have been installed.
»   Use male-to-male connection wire (lengths vary) 
that will connect to each required splitter.
1.   Wiring must be run under 
decking structure and 
behind stringers. DO NOT
run wires between deck 
boards and joists. Staple to 
frame with cable staples at 
least 1/4" (6 mm) wide. 
DO NOT crush wire 
insulation with staple. 
2.   Wiring can be run under deck and behind risers. 
Staple to frame with cable staples at least 1/4"
(6 mm) wide. DO NOT crush wire insulation with 
staple.
3.   Remove 5' (1.52 m) lead wire that is connected to post 
cap and attach wire to post with male connection at 
top of post (female connection would be at bottom of 
post and connect into splitter). Avoid running wire on 
side of post where railing brackets or deck rail lights 
will be installed. Leave approximately 6" (152 mm) of 
lead at top to make connections. Staple to frame and 
posts with cable staples at least 1/4" (6 mm) wide. 
DO NOT crush wire insulation with staple. 
Making Connections
1.   Install splitters to 
inside of framing using 
hardware provided. 
Install at every post 
base where lighting is 
present and depending 
on spacing in between 
each riser and recessed 
light.
2.   Attach male lead from lights to female connections 
on splitter. Also attach male-to-male connection 
wires in between each splitter. Continue until all 
wiring from lights are attached to splitters and 
connector wires are attached in between splitters.
3.   Cap off all unused female connections on splitters 
using caps provided or weather-resistant silicone.
HOW TO INSTALL TREX DECKLIGHTING/CONTINUED
GFCI 
Outlet
Timer
Transformer
To Splitter
Dimmer
(Optional)
1
3
6"
(152 mm)
1
1
2
2
Light
connection
Connection 
wire
Connection wire
3
2
TRANSFORMER CAPACITY BY TYPE
8.3A Transformer
(83 DL TRANSFORMER)
Type of
Light
2.5A Transformer
(2.5 DL TRANSFORMER)
Riser  285  90
Recessed  285  90
Post Cap  85  22
Deck Rail  285  90
Above listing is for maximum number of each individual types of lights. 
If mixing and matching lighting, contact Trex to determine if more than 
one transformer is required.