ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS FAN. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. WARNING: There is a risk of fire, electric shock, or injury to persons. GENERAL SAFETY INFORMATION 1. Your AQUACOOL fan will operate only on 115 Volt AC, 60Hz (cycle) current with a minimum of a 15 Amp circuit. 2.
Assembly instructions 1. 2. 3. Remove pallet straps. Remove metal guard located above evaporative cooling pads. Remove center cooling pad by gently pulling pad out- ward. Additional pads may be removed to allow more access to inside of fan. 4. Check pump for upright position. 5. Check spray bar and splash guard for proper alignment. (see Manual) 6. Replace cooling pads, inserting center pad last. 7 . Attach metal guard over cooling pads and tighten screws. 8.
OPERATING PROCEDURES 1. Connect standard size water hose to water supply. 2. Connect water hose to 3/4 inch adaptor on unit and allow reservoir to fill to capacity. Water flow will automatically shut off at proper level. 3. Align splash guard (curved semicircular pipe located above spray bar). 4. The spray bar should distribute water flow in an upward vertical direction. To adjust the spray bar, gently turn until the bar is angled upward 2-6 degrees facing intake side of cooling pads.
Cooling pads for this evaporative unit are cross-fluted with an intake and discharge side. They are directional, and are clearly marked with arrows to show proper vertical and horizontal installation. When removing pads for maintenance, such as cleaning the interior of unit, always: 1. Disconnect all sources of electricity from unit. 2. Remove screws from metal guard located above pads. 3. Remove center pad first and then remaining pads. 4. When reinstalling pads, insert right and left pads in unit.
Completely dry pads daily to curb algae growth. Clean and flush sump on a regular basis - at least 1- 2 times per week of heavy use. PAD INSTALLATION In order to get the best performance from your cooling pads, they must be installed properly. Pads must always be installed with the steeper flute angle sloping down toward the air entry side. The steeper angle puts more water on the hot, dry side of the pad where it is needed most.